Fig 11
Note: make sure the bag is fastened
securely so that no dust will escape
during operation.
Attach the hose:
Use one hose clamp (P) to connect the
hose (O) to the intake port( Fig 12).
Fig 12
5.2 Dust connection
The hose or ductwork you use to
connect the tool to the dust collector
must be grounded for avoiding
explosion.
(JET Dust Collector Grounding Kit,
Article Number: JW1053).
5.3 Mains connection
Mains connection and any extension
cords used must comply with
applicable regulations.
The mains voltage must comply with
the information on the machine licence
plate.
The mains connection must have a
10 A surge-proof fuse.
Only use power cords marked H07RN-
F
Connections and repairs to the
electrical equipment may only be
carried out by qualified electricians.
6. Machine operation
You can start and stop the machine
with the magnetic switch (R).Machine
Plug(400V) is part(T). Fig 13
Fig 13
7. Maintenance and inspection
General notes:
Maintenance, cleaning and repair
work may only be carried out after
the machine is protected against
accidental starting by pulling the
mains plug.
Inspect the proper function of the dust
collection system daily.
Clean the unit regularly.
Defective safety devices must be
replaced immediately.
Repair and maintenance work on the
electrical system may only be carried
out by a qualified electrician.
7.1 Cleaning Filters
Shake the filter bag whenever it is
clogged and before each collector bag
change.
When the air flow reduces the filter
must be cleaned.
To clean the filter on DC-1200CK-M/T,
turn the handle (I, Fig 10A) a couple of
rotations so the dust falls into the
collector bag.
ATTENTION:
During the changing or cleaning of the
filters it’s necessary to use a mask
(mask with filtration).
7.2 Changing collector bag
Always disconnect the dust collector
from the power source (unplug) before
servicing or changing filter.
During the changing or cleaning of the
collector bag it’s necessary to use a
mask (mask with filtration).
8. Trouble shooting
Unit
doesn’t start
*No electricity-
check mains and fuse.
*Defective switch, motor or cord-
consult an electrician.
Air flow too weak
*
Clogged filter-
Clean filter.
9. Environmental protection
Protect the environment.
Your appliance contains valuable
materials which can be recovered or
recycled. Please leave it at a
specialized institution.
This symbol indicates separate
collection for electrical and electronic
equipment required under the WEEE
Directive (Directive 2012/19/EC) and is
effective only within the European
Union.
10. Available accessories
Stock number 10000315
PVC-hose transparent, Ø100mm,
length 2,5m
Stock number JW1022
Hose clamp Ø100mm
Further dust collection accessories
available, see JET price list.