background image

5

Specifications

AFS-1000B

Stock Number................................................................................................................................ 708620
Outer Filter .................................................................................................................................5 Microns
Inner Filter ................................................................................................................................... 1 Micron
Overall Dimensions (LxWxH/in)............................................................................. 30-1/4 x 24-1/8 x 12-1/8
Sound Rating @ 3ft .......................................................................................................High Speed 69 dB

................................................................................................................................ Medium Speed 67 dB
...................................................................................................................................... Low Speed 62 dB

Air Flow ................................................................................................................. High Speed 1044 CFM

........................................................................................................................... Medium Speed 702 CFM
................................................................................................................................. Low Speed 556 CFM

Motor ...........................................................................................................1/5 HP, 115V, 60Hz, 1 Ph, 6P
Net Weight.......................................................................................................................................54 lbs.
Shipping Weight...............................................................................................................................61 lbs.

Table of Contents

Page

Warranty.................................................................................................................................................. 2
Warnings ................................................................................................................................................. 3
Electrical Requirements ........................................................................................................................... 4
Specifications .......................................................................................................................................... 5
Table of Contents .................................................................................................................................... 5
For Your Own Safety ............................................................................................................................... 5
Contents of Shipping Carton .................................................................................................................... 6
Tools Required for Assembly ................................................................................................................... 6
Assembly..............................................................................................................................................6-7
Controls and Features ..........................................................................................................................7-8
Changing Filters....................................................................................................................................... 8
Breakdown .............................................................................................................................................. 9
Parts List ............................................................................................................................................... 10

FOR YOUR OWN SAFETY

1.

Read and understand instruction manual before installing or operating air cleaner.

2.

To reduce the risk of injury disconnect the air cleaner from the power source (unplug) before servicing
or changing filters.

3.

If ceiling mounted, bottom of air cleaner must be at least 7 feet above the floor.

4.

If ceiling mounted, mounts must be anchored to building structure which will support a minimum of at
least 100 pounds. Never mount to surfaces such as dry wall or false ceiling grids, etc.

5.

To reduce the risk of electrical shock, do not expose air cleaner to water or rain.

6.

Never duct a machine directly into the air cleaner.

7.

To avoid a potentially dangerous situation, do not use this equipment to filter volatile fumes or smoke.
This air cleaner is designed and intended for the filtration of air borne wood dust only. It is neither
designed or intended for any other purpose whatsoever.

8.

Failure to comply may result in serious injury and / or property damage.

The specifications in this manual are given as general information and are not binding. JET Equipment
& Tools reserves the right to effect, at any time and without prior notice, changes or alterations to parts,
fittings, and accessory equipment deemed necessary for any reason whatsoever.

Содержание AFS-1000B

Страница 1: ...OWNER S MANUAL AFS 1000B Air Filtration JET EQUIPMENT TOOLS INC P O BOX 1349 253 351 6000 A WMH Company Auburn WA 98071 1349 Fax 800 274 6840 www jettools com e mail jet jettools com M 708620 5 01...

Страница 2: ...accidents normal wear and tear repair or alterations outside our facilities or to a lack of maintenance THE JET GROUP LIMITS ALL IMPLIED WARRANTIES TO THE PERIOD SPECIFIED ABOVE FROM THE DATE THE PRO...

Страница 3: ...ep tools sharp and clean for best and safest performance Follow instructions for lubricating and changing accessories 16 DISCONNECT TOOLS before servicing and when filters 17 USE RECOMMENDED ACCESSORI...

Страница 4: ...cian or service personnel if the grounding instructions are not completely understood or if in doubt as to whether the tool is properly grounded Use only three wire extension cords that have three pro...

Страница 5: ...changing filters 3 If ceiling mounted bottom of air cleaner must be at least 7 feet above the floor 4 If ceiling mounted mounts must be anchored to building structure which will support a minimum of a...

Страница 6: ...st if it is located away from corners and heating cooling vents If using on sawhorses the air filtration unit should be clamped in place This unit is specifically designed to circulate and filter non...

Страница 7: ...ceiling or wall 2 Place one end of bracket underneath the lip of the cabinet 3 Attach the bracket A Fig 2 with two hex cap screws B Fig 2 and two lock washers C Fig 2 4 Repeat steps for remaining thr...

Страница 8: ...lters Failure to comply may cause serious injury There are two filters that need to be changed The outer filter can easily be removed by disengaging the two clips A Fig 5 Now you can simply pull the f...

Страница 9: ...9 Parts Breakdown...

Страница 10: ...g 1 25 OO1057 Motor 1 CA001000B Capacitor not shown 1 26 NF050800 Nut M5 4 28 708711 Remote Control 1 29 330004 Flange 1 30 330043 PC Board 1 31 OO1023 Eye Bolt 4 32 NH061000 Nut M6 4 33 SN490200 Coun...

Отзывы: