G450 S | G600 S
3 Product description
BA-0003 • 2020-04-09
EN
-
7
3.1.2 G600 S
• Manufactured in accordance with the European standards EN 60974-1 and EN 60974-10
3.1.3 Ambient conditions
The welding power source must only be operated at a temperature between −10°C and +40°C and at
a relative air humidity of up to 50 % at +40°C or up to 90 % at +20°C. The ambient air must be free
of unusually high quantities of dust, acids, corrosive gases or substances etc., other than those that arise
during the welding process.
Fig. 2
G600 S
Tab. 2
G600 S
technical data
Power source
G600 S
Mains voltage, 3 phases
400 V, 50/60 Hz
Fuse
63 A time-lag
Max. power consumption
50 kVA
Setting range
35–600 A, continuous
Operating voltage
21–44 V
Idle voltage
80 V
Duty cycle 35 %
600 A/44 V
Duty cycle 100 %
350 A/34 V
Protection type
IP22
Insulation class
H (180°C)
Type of cooling
F
Weight
210 kg
Dimensions L × W × H
810 × 500 × 850
Содержание G450 S
Страница 18: ...DE 18 BA 0003 2020 10 15 9 Anhang G450 S G600 S Abb 9 Seitenansicht G450 S A B C D E G H F I L K J M N O ...
Страница 21: ...G450 S G600 S 9 Anhang BA 0003 2020 10 15 DE 21 Abb 11 Seitenansicht G600 S A B C D E F G H I J K L ...
Страница 24: ...DE 24 BA 0003 2020 10 15 10 Schaltpläne G450 S G600 S 10 2 Schaltplan G600 S Abb 13 Schaltplan G600 S ...
Страница 25: ...G450 S G600 S Notizen BA 0003 2020 10 15 DE 25 Notizen ...
Страница 41: ...G450 S G600 S 9 Appendix BA 0003 2020 04 09 EN 17 Fig 9 Side view of G450 S A B C D E G H F I L K J M N O ...
Страница 44: ...EN 20 BA 0003 2020 04 09 9 Appendix G450 S G600 S Fig 11 Side view of G600 S A B C D E F G H I J K L ...