Jesco SD 5 00 01/1 Скачать руководство пользователя страница 2

Replacing Mechanical Seals

SD 5 00 01 / 2

Lutz-Jesco GmbH

Improved changes are always reserved without notice.

How to replace a mechanical seal (B2i version)

Important!

The pump must be disconnected electrically to make sure that the motor
does not start unintentionally.

a)

Loosen cap nuts 

1

.

b)

Remove spacer bolt 

2

 from spiral casing 

3

 and casing flange 

4

.

c)

Pull away casing flange 

4

 and spiral casing 

3

 towards the front.

d)

Unscrew impeller cap 

5

Caution!!! Left-hand thread.

e)

Remove safety pin 

6

.

f)

Unscrew crown nut 

7

 

(left-hand thread)

 and remove washer 

8

.

g)

Push impeller 

9

 smoothly towards the front using two assembly levers.

h)

Remove mechanical seal 

10

 now visible with two srew drivers towards the front.

i)

Push back-plate 

11

 with counter-ring flange 

12

 out of spacer 

13

 using two

assembly levers.

j)

Loosen screws 

14

 at counter-ring flange 

12

.

k)

Push counter-ring of mechanical seal 

10

 from rear out of counter-ring flange 

12

.

For reassembly proceed in reverse order.

During disassembly please check the following:

- Has shaft protection sleeve 

15

 been damaged?

- Has the seat of counter-ring flange 

12

 been damaged?

- Have other components been damaged or are they worn out?

All o-rings should be replaced when assembling a dismounted pump.

Отзывы: