Hydraulic installation
Hydraulic accessories
23
© Lutz-Jesco GmbH 2015
Subject to technical changes.
150225
BA-10221-02-V03
Stepper Motor-driven Diaphragm Dosing Pump
MAGDOS LK
Operating Instructions
a
b
c
f
h
i
j
d
e
g
Fig. 21: Installation with a pulsation dampener
No.
Description
a
Main line
b
Injection nozzle with shut-off valve
c
Pulsation dampener
d
Chemical tank
e
Pressure line
f
MAGDOS LK dosing pump
g
Wall bracket
h
Suction pulsation dampener
i
Suction line
j
Shutoff valve
Tab. 15: Designation of components
8.7.6 Priming aid
Priming aids are particularly advisable:
n
in the case of dosing pumps with small volumetric displacements per
stroke or with low stroke length settings,
n
with high uction heads,
n
with highly dense dosing media,
n
at priming for the first time due to dry valves and air in the suction line
and the dosing head,
n
in dosing systems with frequent downtimes.
Further advantages resulting from priming aids:
n
preventing cavitation in the suction line,
n
gas removal,
n
optical dosing control with small amounts,
n
smoothing of the suction flow.
a
b
e
c
f
d
g
Fig. 22: Installation with a priming aid
No.
Description
a
Main line
b
Injection nozzle with shut-off valve
c
Priming aid
d
MAGDOS LK dosing pump
e
Wall bracket
Tab. 16: Designation of components
Содержание MAGDOS LK