62
13. T
roubleshooting
Problem
Possible Cause
Recommended Action
Dosing pump not delivering or
Check
valves
leaking
or
blocked.
Clean
check
valves
and
output too low.
bleed
dosing
head.
See also start-up of pump.
Check valves incorrectly installed.
Reassemble check valves.
Ensure that valve balls are located
above valve seats.
Suction valve or suction line
Clean
or
seal
suction
line.
leaking or blocked.
Suction
lift
too
high.
-
Install dosing pump at lower position.
-
Install pulsation dampener on
suction side.
-
Install priming aid.
Viscositiy
too
high.
-
Install spring-loaded check valves.
-
E
nlarge suction and discharge line/diameter
.
-
Use special dosing head
>> Contact Lutz-Jesco.
No stroke movement
St
roke length set to zero.
Correctly
adjust
pump
stroke
length.
observed.
D
iaphragm return spring broken.
Replace spring.
Fuse
blown.
Check power supply voltage,
inform Lutz-Jesco service.
Power
supply
interrupted.
Switch on power supply voltage.
Solenoid
defective.
Check coil resistance and isolation;
replace solenoid, if required. Refer to page 59.