11.5 Valves
The dosing pump valves must be cleaned regularly.
NOTE!
When screwing the valves into the dosing head, observe the tightening torque of 2 Nm ±20 %.
CAUTION!
Chemical may spray out. This may lead to chemical or other burns. The dosing pump must always be
depressurised and rinsed with water or a suitable medium before starting any work on the dosing pump.
NOTE!
Dirty valves will affect the dosing accuracy.
11
2
3
5
4
Maintenance | Operating Manual FEDOS E/DX |
29
Содержание FEDOS E 5
Страница 47: ...Notes Notes Operating Manual FEDOS E DX 47...