MODEL
FLOAT SIZE
P/N
JX_1F
2-3/4" OD x 5" Long
D-4171-13
JX_2F
3-1/2" OD x 6" Long
D-4261-13
JX_3F
3-1/2" OD x 6" Long
D-4251-13
JX_4F
3-1/2" OD x 6" Long
D-4291-13
JX_5F
3-1/2" OD x 6" Long
D-4241-13
JX_6F
5-1/2" OD Sphere
D-3361-13
JX_7F
5-1/2" OD Sphere
D-3341-13
JX_8F
5-1/2" OD Sphere
D-3331-13
JX_9F
7" OD Sphere
D-3431-13
SPARE FLOATS
SWITCH SWITCH TYPE
P/N
X4
SPDT
K-2008-00
D4
SPDT Hi Temp.
K-2009-00
H4
SPDT Herm. Sealed
K-2011-00
P4
SPDT Gold Plated
K-2010-00
E4
SPDT Hi Temp. Encapsulated
K-2020-00
X8
DPDT
K-2012-00
D8
DPDT Hi Temp.
K-2013-00
H8
DPDT Herm. Sealed
K-2015-00
P8
DPDT Gold Plated
K-2014-00
E8
DPDT Hi Temp. Encapsulated
K-2021-00
SPARE SWITCH MECHANISMS
12
Switch Mechanism Replacement
IMPORTANT NOTE
If a spare switch mechanism is fitted at any time, it is important that the magnet system is left in the correct mode.
After installation of a replacement switch mechanism, always check that the B-B contacts are made, assuming the
chamber is empty of liquid. If the chamber is full of liquid, then A-A contacts should be checked to ensure they are made.
If it is found that a switch mechanism is not in the correct mode, and the switch is located on the pressure tube to allow it to
trip in both directions, then the liquid level in the chamber should be raised such that the primary float magnet passes
through the switching point. Lowering the liquid level will then cause the float magnet to fall back through the switching
point, thus leaving the switch mechanism in the correct operating mode. (For a switch operating as low level alarm, the
liquid level should be first lowered then raised back to ensure the switch mechanism is in the correct operating mode).
Full fitting instructions are supplied with each spare or replacement switch mechanism.
TEMPERATURE EXTENSION
Standard, No Temperature Extension
3" Temperature Extension
6" Temperature Extension / Cooling Fins
X9F
1 Switch
3 Switches (Requires LA4N Enclosure)
STANDARD SPARE FLOAT & ROD ASSEMBLY
Base Part Number
FLOAT / ROD DESCRIPTION
NUMBER OF SWITCHES
P/N
S23991
CODE
3-1/2" OD x 6" Long, Float w/ Std Length Rod
X8F
X7F
X6F
X5F
X4F
X3F
2 Switches
X2F
X1F
2-3/4" OD x 5" Long, Float w/ Std Length Rod
7" OD, Float w/ Std Length Rod
5-1/2" OD, Float w/ Std Length Rod
5-1/2" OD, Float w/ Std Length Rod
5-1/2" OD, Float w/ Std Length Rod
3-1/2" OD x 6" Long, Float w/ Std Length Rod
3-1/2" OD x 6" Long, Float w/ Std Length Rod
S23991
X3F
3
2
-
3-1/2" OD x 6" Long, Float w/ Std Length Rod
3
2
1
CODE
-
-
F
3
(Omitted)
CODE
www.Jerguson.com
●
JergusonApp@clark
‐
reliance.com
●
+1.440.572.1500
15
1
(1)
Spare
switch
mechanism
is
recommended
for
every
(10)
installed
switch
mechanisms.
Refer
to
model
no.
for
switch
mechanism
quantity,
pages
4
&
5.
2
Refer
to
page6,
'Electrical
rating'
table,
for
switch
mechanism