background image

Jergens Work Holding Solutions    -    C-Box Pump, Use and Maintenance Booklet    -    4-06-16

 

Page 4 

Description and Start Up Procedures 

 
Pumps must be installed in a horizontal position. Be sure that suction lines from the 
manifold to the hydraulic fluid are as straight as possible and do not have high 
points to trap air. Suction lines should be at least ¼” inside diameter and steps 
should be taken to ensure the hydraulic fluid is kept commercially clean. The air inlet 
connection should have piping of at least 1/8” bore and be kept to the shortest 
length possible to keep pressure losses to a minimum. 

These operations should be 

carried out by qualified personnel. 

 
It is advisable to use or maintain: 
 

 

Hydraulic oil having viscosity of 150 to 250 SSU 

 

Oil temperature 32º F to 150º F 

 

Air temperature 40º F to 100º F 

 

 
Compressed Air System 

 
It will be advisable to fit an air filter/regulator unit having maximum flow capacity of 
at least 5 scfm. Use tubing of at least ¼” inside diameter to avoid pressure losses. 
 

Hydraulic System 

 
Valves, pipes, hoses and accessories should all correspond to maximum working 
pressure of the pump in order to ensure the 

safety of all persons

 nearby. 

Components should always be of a size that will fulfill flow requirements without 
unnecessary pressure losses. 

 
Priming and Initial Operation 

 
After connecting the pump to air and oil circuitry, loosen the first hydraulic 
connection to allow entrapped air to bleed out. Allow the pump to operate with 20 
PSI air pressure until the oil flows from the loose joint and then tighten the joint. 
Always observe strict safety and protection during this operation. Adjust settings until 
smooth operation is achieved.  

Содержание 61763

Страница 1: ...71982 ELBOW 4 1 754642 COMBINATION FILTER REGULATOR 5 3 773046 CONNECTOR FITTING 6 1 61954 COUPLER NIPPLE 7 20 61112 3 8 TUBING FT REV REVISION RECORD DATE DR CLEVELAND OH U S A CAD GENERATED DRAWING...

Страница 2: ...n Guarantee and Identification Plate Description Start Up Procedures Description of Working Parts Storage and Disposal Fault Finding Maintenance and Weights Spare Parts Assembly Drawing Jergens 15700...

Страница 3: ...hen contacting our service center specify the pump model and serial number this will help us to respond quickly and effectively Guarantee Jergens pumps are guaranteed both for the quality of materials...

Страница 4: ...Jergens Work Holding Solutions C Box Pump Use and Maintenance Booklet 4 06 16 Page 3 Identification Plate shows Serial Number Jergens Model Code...

Страница 5: ...0 SSU Oil temperature 32 F to 150 F Air temperature 40 F to 100 F Compressed Air System It will be advisable to fit an air filter regulator unit having maximum flow capacity of at least 5 scfm Use tub...

Страница 6: ...hydraulic pressure can be adjusted using the ratio of the pump As the hydraulic load from the circuit increases and the oil pressure rises the pump will slow down and eventually stop In this way the...

Страница 7: ...ntrol valves are used Pressurized oil from the system will be released internally back to tank when pilot air pressure is applied to the 1 8 NPT connections shown below A small pneumatic valve can be...

Страница 8: ...Pump Use and Maintenance Booklet 4 06 16 Page 7 Description of the Standard Pump Components A Air Cylinder B Air Valve C Air Inlet 1 8 NPT E Air Muffler F Oil Chamber Interface G Oil Suction Inlet Ga...

Страница 9: ...l calculation because of small frictional losses from both air and oil seals After the pump suction is connected to the oil supply connect the compressed air supply at a low pressure 20 PSI recommende...

Страница 10: ...ed suction line 4 1 Clean out filter pumping oil 4 2 Bad connection on 4 2 Check for bad suction line connections or air leaks on suction line 4 3 Check valves blocked 4 3 Clean or replace or worn val...

Страница 11: ...t within reach of children since they are potential source of danger Be sure to dispose of pollutant or non biodegradable materials in the correct way Materials must be disposed of in accordance with...

Страница 12: ...2 773682 M3 X 30MMLG SHCS 16 1 773683 OIL CHAMBER 15 1 773684 AIR VALVE GASKET 14 2 771823 O RING 2 015 13 2 773685 CHECK VALVE 12 2 773686 5 16 18 X 3 3 4 LG SHCS 11 4 770558 1 4 20 X 1 LG SHCS 10 2...

Страница 13: ...G 2 011 17 1 773684 AIR VALVE GASKET 16 2 773694 CHECK VALVE 15 2 770577 3 8 16 X 3 LG SHCS 14 8 770556 1 4 20 X 3 4 LG SHCS 13 2 770594 10 32 X 3 4 LG SHCS 12 1 773695 OIL CHAMBER 11 2 753083 O RING...

Отзывы: