background image

                                                                                                                          

 

 

 

 

Operating Instructions 

 

Small-Size Electroplating Unit 

 

DIGITAL II Version 2.0

 

 

 

 

 
 
 
 

Jentner Plating Technology GmbH

 

Johann-Staib-Strasse 2| 75179 Pforzheim 

 Germany

 

Tel.: 07231 

 418 094-0 | FAX 07231 

 418 094-77

 

[email protected]

www.jentner-plating.com

 

 

 

Содержание DIGITAL II

Страница 1: ...ions Small Size Electroplating Unit DIGITAL II Version 2 0 Jentner Plating Technology GmbH Johann Staib Strasse 2 75179 Pforzheim Germany Tel 07231 418 094 0 FAX 07231 418 094 77 info jentner de www j...

Страница 2: ...ht 250 mm weight 18 kg The DIGITAL II Version 2 0 includes 8 tanks PP 4 working and 4 rinsing tanks Dimension 150 x 100 x 150 mm Volume 1 5 litre 1 safety protection cable 1 thermo couple with titaniu...

Страница 3: ...ure Button Volt setting voltage Button Charge setting Amin charge Button Time setting of exposure time Button Basin selection of the working tank Button OK save of the set values Button Prog selection...

Страница 4: ...uctive contact The required anode material for example stainless steel MOX fine silver platinized titanium depends on each plating bath Please note the information in the data sheets of the chemical p...

Страница 5: ...unit is short circuit proof if there will be short circuit between cathode and anode The fuse is located on the backside of the machine situated in main connection socket inside fuse holder Only micr...

Страница 6: ...ion 2 0 Example Charge Rhodium bath Each plating bath uses a theoretical deposition value eg Rhodium approximately 6 mg Amin value see product description You can now choose whether a deposition time...

Страница 7: ...inum Ni Nickel Cu Copper The programs from 1 to 6 are unnamed For each tank up to 3 programs can be installed Approach to programming 1 Turn on main switch 2 Press button progr 3 Select with the rotar...

Страница 8: ...done for this process Do as following 1 Press button basin 3 seconds 2 Enter the desired value and basin 3 Press save 4 Leave with OK 5 Press button progr and choose the desired one 6 Set the same bas...

Страница 9: ...Side 9 Operating Instructions DIGITAL II Version 2 0...