manualshive.com logo in svg
background image

 

 

10/25/2018 

643 SO. DUGGAN AVENUE • AZUSA, CALIFORNIA 91702-5185 
           (626) 969-

7991 • (661) 324-3378 • FAX (626) 969-4991

 

 

RAINSWITCH Retrofit/Upgrade Instructions 

to convert a JIC-RS100-A to JIC-RS100-B 

 

 
 
 
Purpose of Retrofit: 

 

 

The

 

“-A” version 

rainswitch used a Pepperell-Fuchs capacitance sensor, 

which is a 30mm green plastic proximity sensor. Due to its lack of repeatability 
from apparent sensitivity to installation ground, and susceptibility to fouling from 
dirt and debris collecting on the face of the sensor, a redesign was necessary. 
This level sensor activates 

a relay mounted in the “Pilot Station”. 

 
 

The 

“-B” version

 rainswitch 

uses a conductivity sensor probe with a ½” 

MNPT connection to the rainswitch. A level controller is mounted in the “Pilot 
Station” in place of the relay used in the “-A” version. This controller sends a very 
small current to the probe, so the circuit is completed as soon as water touches 
the probe, and after the 3 second delay, switches the contacts in the controller. 
This has proven to be extremely repeatable, and not subject to fouling. 
 

 

Parts Required: 

 

#JIC-RLSK

 Level Sensor Kit, consists of two parts: 

 

#R-PHST-12GT-2 Level Probe 

 

#JIC-

RS ADAPTOR, 30mm female x ½” FNPT, 316SS 

 

#WFLT-DM-2011-TD

 Level Control Relay. Usually remote mounted as existing 

Pilot Station is too small for this relay. 

 
 OR NEW PILOT STATION: 

#JIC-AT1PB2L-C

 

Auto-Reset Pilot Station 

#JIC-1PB2L-C

 

Manual Pilot Station

 

 
 
 