Analog Dispenser User's Manual  

 
Jensen Global’s compact analog shot meter allows for reproducible 
deposits of a wide range of thin or viscous materials and provides 
ergonomic relief. 
 
Items included with this system are: 
 

  A foot switch with 6 ft. cord that actuates the unit  

  3 cc, 5 cc, 10 cc, and 30cc XHP adapters with 3 feet of 5/32” 

tubing and a push to connect fitting 

  2 each of our luer lock air barrels and stoppers  

  A sample kit, which contains a variety of dispensing tips 

 
This system has two LED indicators: 
 

  Top LED is the Power Indicator 

o

  Off – unit’s power is off 

o

  Red - unit is in Manual mode 

o

  Green – unit is in Auto mode 

 

  Bottom LED is the Solenoid Indicator 

o

  Red – solenoid is on 

o

  Off – solenoid is off 

 

To switch between Manual and Auto Mode, press the white button below 
the solenoid indicator.  

 
Manual Mode 

 
Press the pedal down on the foot switch to start dispensing. Hold the 
pedal down to continue dispensing. Release the pedal to stop. The 
solenoid indicator light mirrors the dispensing of product.  
 

Auto Mode 

 

In this mode, the user can preset a time for dispensing. To set or change 
the desired time for dispensing, simply rotate the timer knob in directions 
following the + or - sign. The 0-100% is calibrated to the maximum time 
selected (See Maximum Time Selection on next page). 

 
 
 
 

 

Time Range Adjustments 

 

The dispenser is defaulted at a time range or .01 – 10 seconds. 
You can change the timer to any of the ranges listed below by 
holding the white button located above the timer knob while 
powering on. Continue to hold for 10 seconds until both LEDs 
light up amber. 

 

Release the button and the LEDs will display one of 7 options 
using combinations of on, off, red, and green. 
 
Press the white button after powering on cycles through the 7  
time options below: 
 

1 sec -- top green, bottom off 
5 sec – top off, bottom green 
10 sec – top green, bottom green – default 
20 sec – top red, bottom off 
30 sec – top off, bottom red 
60 sec – top red, bottom red 
120 sec – top green, bottom red 

 
Turning the power off while the time option chosen is displayed  
will select that option as the new default when powering on. 
 

Troubleshooting 

 

1) 

Dispenser does not turn on

Check the power connector on the back and make sure it is 
pushed in completely. 

 
2) 

I hear air leaking.

 

The vacuum may be on. Turn the vacuum knob on the front 
of the unit clockwise until the hissing stops. Also check your 
air connector fitting in the back of the unit for a tight fit. Use 
Teflon™ tapes if necessary. 

 

3) 

Everything is on and seems to be working, but no 
material dispenses out of the syringe

.

  

Check the white adapter fitting that connects to the center 
left of the dispenser, ensuring it is pushed in all the way. 
Also check to see that you have air pressure and the gauge 
is reading above 0 psi.  
 
Continued on next page. 
 
 