9
When the platemeter is switched on, it will display the default setting of:
140
500
0.0.0.0 (The decimal points will flash 3 times indicating a negative, of any
number the user has entered and saved.)
Any changes to the formula will be retained and displayed next time the plateme
-
ter is switched on.
When the platemeter is used with a negative number activated and the result in
kg of dry matter is < “0”, then the LCD will display “0000”. The platemeter will still
beep with each plonk and continue to count. The hyphens will flash on and off
with each beep. An “Actual” negative number cannot be displayed.
A positive number result after calculation will still show as a positive number as
normal.
Examples:
Assume the formula used is (h x 140) + 500 – 1000
If the average “h” (height) = 4.0 then:
(4 x 140) + 500 – 1000 would result in a display of “60” kg
Any negative number entered by the user is saved to memory and ready to use
next time. If, in the menu the “F- - d” option is selected, then all settings are reset
to 140, 500, 0000