Gas Supply Requirements

Observe all governing codes and ordinances. 
IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest 
edition. 
IMPORTANT: Leak testing of the range must be conducted 
according to the manufacturer’s instructions.

Type of Gas 

Natural Gas:

This cooktop is listed by Underwriters Laboratories (UL/cUL) for 
use with Natural gas or, after proper conversion, for use with LP 
gas. 

This cooktop is factory-set for use with Natural gas. To 
convert to LP gas, see the Gas Conversion instructions 
provided in the package containing the literature. The model/
serial rating plate located on the underside of the burner box 
has information on the types of gas that can be used. If the 
types of gas listed do not include the type of gas available, 
check with the local gas supplier.

LP Gas conversion:

Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting the serving gas supplier. See the Gas 
Conversion instructions provided in the package containing the 
literature.

Gas Supply Line 

Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the 
cooktop location. A smaller size pipe on longer runs may 
result in insufficient gas supply. Pipe-joint compounds that 
resist the action of LP gas must be used. Do not use 
TEFLON

®†

 tape. With LP gas, piping or tubing size can be ½" 

minimum. Usually, LP gas suppliers determine the size and 
materials used in the system.

Flexible metal appliance connector:

If local codes permit, use a 

⁵⁄₈

" flexible stainless steel 

tubing gas connector, designed by CSA to connect the 
cooktop to the rigid gas supply line. 

A ½" (1.3 cm) male pipe thread is needed for connection 
to the female pipe threads of the inlet to the appliance 
pressure regulator. 

Do not kink or damage the flexible metal tubing when 
moving the cooktop.

Must include a shutoff valve: 
The supply line must be equipped with a manual shutoff 
valve. This valve should be located in the same room but 
external to the cooktop opening, such as an adjacent 
cabinet. It should be in a location that allows ease of opening 
and closing. Do not block access to shutoff valve. The valve 
is for turning on or shutting off gas to the cooktop.

Gas Pressure Regulator

The gas pressure regulator supplied with this cooktop must be 
used. The inlet pressure to the regulator should be as follows for 
proper operation:
Natural Gas:

Minimum pressure: 6" (15.2 cm) WCP
Maximum pressure: 14" (35.5 cm) WCP
LP Gas:

Minimum pressure: 11" (27.9 cm) WCP
Maximum pressure: 14" (35.5 cm) WCP
Contact local gas supplier if you are not sure about the inlet 
pressure.

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 

Examples of a qualified person include: 

licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.

A. Gas supply line
B. Shutoff valve “open” position

C. To cooktop

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

A

B

C

Содержание W10676381C

Страница 1: ...on 17 SCH MA DE C BLAGE 18 You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potenti...

Страница 2: ...er WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detect...

Страница 3: ...ening dimensions that are shown must be used Given dimensions are minimum clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be ava...

Страница 4: ...onal Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circ...

Страница 5: ...be minimum Usually LP gas suppliers determine the size and materials used in the system Flexible metal appliance connector If local codes permit use a flexible stainless steel tubing gas connector des...

Страница 6: ...nless steel gas supply line can be assembled to the cooktop before or after the cooktop is installed See the Make Gas Connection section 1 Remove the foam strip from the hardware package Remove the ba...

Страница 7: ...use with LP gas to the larger thread ends of the flexible connector adapters see B and F in the following illustration 2 Attach 1 adapter to the gas pressure regulator and the other adapter to the ga...

Страница 8: ...racter No yellow tip blowing or lifting of flame should occur Occasional orange flashes are normal and reflect different elements in the air or gas 3 Repeat for the Lo position 4 Repeat for the Sim po...

Страница 9: ...s pushed in and rotated from 0 to 210 counterclockwise from Off 120 VAC 60 Hz 1 Phase 15 Amp GND Power Cord Plug L1 GND N GN BK BK WH WH 1 WH 2 WH 3 WH 4 WH 5 Spark Modules BK Valve Switches RF L1 N N...

Страница 10: ...AVERTISSEMENT Si les renseignements dans ce manuel ne sont pas exactement observ s un incendie ou une explosion peut survenir causant des dommages au produit des blessures ou un d c s Ne pas entrepos...

Страница 11: ...cher de l emplacement d installation de la table de cuisson doivent tre scell es Respecter les dimensions indiqu es pour les ouvertures d couper dans les meubles Ces dimensions constituent les valeurs...

Страница 12: ...i le placard comporte un tiroir on devra m nager un d gagement de 4 10 2 cm ou plus entre le plan de travail et le dessus du tiroir ou autre obstacle dans le placard inf rieur Il pourra tre n cessaire...

Страница 13: ...us r cente dition du code national en vigueur National Fuel Gas Code ANSI Z223 1 ou CAN CGA B149 IMPORTANT Les tests de fuite de la table de cuisson doivent tre effectu s selon les instructions du fab...

Страница 14: ...e utilis La pression d alimentation du d tendeur doit tre comme suit pour un fonctionnement correct Gaz naturel Pression minimum 6 15 2 cm colonne d eau Pression maximum 14 35 5 cm colonne d eau Gaz p...

Страница 15: ...cuisson avant de monter cette derni re dans le placard Voir la section Raccordement au gaz Table de cuisson sur four encastr IMPORTANT Ne pas utiliser de brides de fixation 1 Installer la table de cu...

Страница 16: ...de la configuration d installation Raccordement typique par raccord flexible 1 Appliquer un compos d tanch it des filetages r sistant au propane sur l extr mit filet e la plus grosse des adaptateurs d...

Страница 17: ...t tre sup rieur 4 secondes du fait de la pr sence d air dans la canalisation de gaz 2 V rifier que la flamme est bleue la position Hi Elle doit tre propre et douce On ne doit pas observer de pointe ja...

Страница 18: ...ns le sens anti horaire entre 0 et 210 depuis la position d arr t Terre Ph1 Terre NEU VE N N BL BL 1 BL 2 BL 3 BL 4 BL 5 N AvD Ph1 Neu Neu ArD N N N C Neu Ph1 C ArG Neu Ph1 N N N N N N C AvG Neu Ph1 l...

Страница 19: ...19 Notes...

Страница 20: ...W10676381C 2014 Jenn Air Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s 5 14 Printed in U S A Imprim aux U...

Отзывы: