19
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
2. Test all connections by brushing on an approved noncorrosive
leak-detection solution. If bubbles appear, a leak is indicated.
Correct any leak found.
3. Remove cooktop burner caps and grates from package
containing parts. Align recess in burner caps with pins in
burner base. Burner caps should be level when properly
positioned. If burner caps are not properly positioned, surface
burners will not light. Place burner grates over burners and
caps.
Connect Range to Downdraft System
1. Attach flexible vent (provided) to the blower motor inlet using a
vent clamp.
2. Check countertop height to allow range top to clear
countertop. Adjusting leveling legs if necessary.
3. Remove access panel by grasping both sides, pulling upward,
and lifting out.
4. Move range close to cabinet opening.
5. Plug range into grounded outlet (if using a power supply cord).
6. Plug range electrical connector into the downdraft blower
motor.
7. Remove cardboard or hardboard from under the range. Using
2 or more people, gently move range into its final location.
8. Check that the anti-tip bracket is installed and that electrical
cords are not kinked. Use a flashlight to look underneath the
bottom of the range.
■
Look for the anti-tip bracket securely attached to floor or
wall.
■
Slide range back so rear range foot is under anti-tip
bracket.
9. Level the range.
a.) Place rack in oven.
b.) Place level on rack and check levelness of the range, first
side to side; then front to back.
c.) If range is not level, pull range forward until rear leveling
leg is removed from the anti-tip bracket.
d.) Use a wrench or pliers to adjust leveling legs up or down
until range is level.
e.) Push range back into position.
f.) Check that rear leveling leg is engaged in anti-tip bracket.
NOTE: Range must be level for satisfactory baking performance.
10. Depending on your installation, connect the flexible vent from
the blower motor inlet to the range using a vent clamp.
A. Closed valve
B. Open valve
A. Inlet flexible vent
B. Vent clamp
A. Power supply cord (on some installations)
B. Range electrical connector to blower motor
A
B
1
2
1
A
B
A
B
Содержание W10253464B