Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing  
any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.

JENN-AIR

®

 DETAILED PLANNING DIMENSIONS

2 of 4

JRC120072A  07/2012  

OPENING/CLEARANCE DIMENSIONS

48"/36" CUSTOM HOOD LINERS

UXL6048YSS – 47

7

8

" x 11

1

2

" x 22"

UXL6036YSS – 35

7

8

" x 11

1

2

" x 22"

ELECTRICAL REQUIREMENTS 

120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit  
is required.  

VENTING REQUIREMENTS 

An internal or in-line (external) blower motor system is required. 
The hood is factory set for venting through the roof or wall.  
Do not terminate the vent in an attic or other enclosed area.

LOCATION REQUIREMENTS 

Custom built enclosure with hood liner support. Hood support  
must be able to support 75 lb (34.0 kg).

FRONT VIEW

MODEL #

UXL6048YSS

UXL6036YSS

in

cm

in

cm

A

Width of vent entry location – ceiling option (min.-max.)

12-14

30.5-35.6

12-14

30.5-35.6

B

Width of vent entry location – wall option (min.-max.)

12-14

30.5-35.6

12-14

30.5-35.6

C

Width of cabinet opening (min.)

48

121.9

36

91.4

D

Height from vent entry location to ceiling – wall option (min.)

2

5.1

2

5.1

E

Height from hood to vent entry location – wall option (min.)

18

45.7

18

45.7

F

Suggested distance from hood to electric cooking surface (min.-max.)

24-36

61.0-91.4

24-36

61.0-91.4

Suggested distance from hood to gas cooking surface (min.-max.)

30-36

76.2-91.4

30-36

76.2-91.4

G

Height from upper cabinet to countertop (min.)

18

45.7

18

45.7

H

Depth of vent entry location – ceiling option

17

43.2

17

43.2

I

Distance from centerline to cutout for hood liner

14

35.6

14

35.6

J

Width of cutout for hood liner 

28

71.1

28

71.1

K

Depth from cutout to wall

4

1

2

11.4

4

1

2

11.4

L

Depth of cutout for hood liner

13

33.0

13

33.0

e

Terminal box location

v

Recommended vent entry location

v

v

A

B

C

H

D

E

F

e

J

L

G

K

Centerline of 

Hood Support

I

CUTOUT VIEW

v

v

A

B

C

H

D

E

F

e

J

L

G

K

Centerline of 

Hood Support

I