23
3.
Unscrew the metal cover and unscrew the blue regulator cap.
Keep the washer in place.
4.
Flip the blue regulator cap over and screw it back into the
metal cover.
5.
Screw the metal cover securely back into place. Do not
overtighten.
To Convert Surface Burners (Natural Gas to LP Gas)
1.
If installed, remove the burner grates.
2.
Remove the burner caps.
3.
Remove the burner base.
4.
Apply masking tape to the end of a
⁹⁄₃₂
" (7 mm) nut driver to
help hold the gas orifice spud in the nut driver while changing
it. Press nut driver down onto the gas orifice spud and
remove by turning it counterclockwise and lifting out. Set gas
orifice spud aside.
5.
Remove the orifice spuds shipped in the literature package in
the oven. Gas orifice spuds are stamped with a number,
marked with 1 or 2 color dots, and have a groove in the hex
area. Replace the Natural gas orifice spud with the correct LP
gas orifice spud.
Refer to the following chart for correct LP gas orifice spud
ratings and to spud holder card for proper placement.
LP Gas Orifice Spud Chart for Surface Burners
*Not in all kits/models.
NOTE:
Refer to the model/serial/rating plate located on the oven
frame behind the top right-hand side of the oven door for proper
sizing of spuds for each burner location.
6.
Place Natural gas orifice spuds in the orifice spud bag.
IMPORTANT:
Keep the Natural gas orifice spuds in case of
reinstallation with Natural gas.
7.
Replace the burner base.
8.
Replace burner cap.
9.
Repeat steps 1 to 7 for the remaining burners.
10.
Replace the baking drawer. See the “Remove/Replace
Drawer” section.
Complete Installation (Natural Gas to LP Gas)
1.
Refer to the “Make Gas Connection” section for proper
connection of the range to the gas supply.
2.
Refer to the “Electronic Ignition System” section for proper
burner ignition and operation.
3.
Refer to the “Adjust Flame Height” section for burner flame
adjustments.
IMPORTANT:
You may have to adjust the low setting for each
cooktop burner.
Checking for proper cooktop burner flame is very important.
Natural gas flames do not have yellow tips.
4.
Refer to “Complete Installation” in the “Installation
Instructions” section of this manual to complete this
procedure.
A. Metal cover
B. Washer
C. Blue regulator cap
A. Natural gas position
B. LP gas position
A. Igniter electrode
B. Burner cap
C. Gas tube opening
D. Burner base
A. Igniter electrode
B. Orifice spud
C. Orifice spud holder
D. Screws
A
B
A
C
A
B
D
A
B
C
A
B
C
D
A. LP groove
Burner Rating/
Type
Color
Size
(mm)
ID
Number
Placement
15,000 BTU/
Stacked*
Silver
Black/Orange
1.05
0.32
L105
L32
LF
14,200 BTU/
Ultra/Stacked*
Silver
1.05
L105
LF/RF
8,000 BTU/
Semi
Red/Orange
0.85
L85
RR/CTR
5,000 BTU/
Auxi
Red/Blue
0.65
L65
LR
1,200 BTU/
Stacked/
Simmer*
Black/Orange
0.32
L32
LF
(Simmer)
A
IMPORTANT:
Make sure to save the orifices that have
just been replaced in the conversion.