Cabinet Dimensions

IMPORTANT:

Minimum distance “X”: 30" (76.2 cm)
Suggested maximum distance “X”: 36" (91.4 cm)

Venting Requirements 

Vent system must terminate to the outdoors.

Do not terminate the vent system in an attic or other enclosed 
area.

Do not use a 4" (10.2 cm) laundry-type wall cap.

Use metal vent only. Rigid metal vent is recommended. 

The length of vent system and number of elbows should 
be kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61.0 cm) of straight 
vent between the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

Use clamps to seal all joints in the vent system.

The vent system must have a damper. If roof or wall cap has 
a damper, do not use damper supplied with the range hood.

Use caulking to seal exterior wall or roof opening around the 
cap.

The size of the vent should be uniform.

Cold Weather Installations

An additional back draft damper should be installed to minimize 
backward cold air flow and a thermal break should be installed to 
minimize conduction of outside temperatures as part of the vent 
system. The damper should be on the cold air side of the thermal 
break.
The break should be as close as possible to where the vent 
system enters the heated portion of the house.

Makeup Air

Local building codes may require the use of makeup air systems 
when using ventilation systems greater than specified CFM of 
air movement. The specified CFM varies from locale to locale. 
Consult your HVAC professional for specific requirements in your 
area.

Venting Methods

This canopy hood is factory set for venting through the roof or 
wall.
A 3

¹⁄₄

" x 10" (8.3 x 25.4 cm) rectangular vent system is needed for 

installation (not included). The hood exhaust opening is 3

¹⁄₄

" x 

10" (8.3 x 25.4 cm). Vent system can terminate either through the 
roof or wall. To vent out of the top of the range hood and through 
a wall, a 90° elbow is needed. See “Install Range Hood” section 
for details for installing the damper.

NOTE:

 Flexible vent is not recommended. Flexible vent creates 

back pressure and air turbulence that greatly reduce 
performance.

A. 76" (193.0 cm) minimum for 

installations with canopy only.

B. 88" (223.5 cm) minimum for 

installations with optional 
duct cover.

1

⁹⁄₃₂

"

(3.2 cm)

8

¹⁄₈

" (20.6 cm): 30" (76.2 cm) models

11" (27.9 cm): 36" (91.4 cm) models 

Wiring knockout

7

⁷⁄₈

"

(20.0 cm)

12

³⁄₁₆

" (31.0 cm): 30" (76.2 cm) models 

12

¹⁄₈

" (30.8 cm): 36" (91.4 cm) models 

¾" 

(1.9 cm)

13" (33.0 cm)

 

18" (45.7 cm) min.

 

 

clearance upper

cabinet to countertop

36" (91.4 cm)

countertop height

30" (76.2 cm) or 36" (91.4 cm) 

cabinet opening width

(If installed between cabinets)

A B

 

 X

 

Bottom  of canopy 

 

to cooking surface

 

 

Min. cabinet 

opening width

Duct cover (if used)

Canopy

Содержание JXU9130WP0

Страница 1: ...536 6247 or visit our website at www jennair com In Canada call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair ca Instructions d installation et Guide d utilisation et d entretien A...

Страница 2: ...TTE 25 Nettoyage 25 SCH MA DE C BLAGE 26 ASSISTANCE OU SERVICE 27 Au Canada 27 Accessoires 27 GARANTIE 28 RANGE HOOD SAFETY You can be killed or seriously injured if you don t immediately You can be k...

Страница 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS...

Страница 4: ...installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the ve...

Страница 5: ...as close as possible to where the vent system enters the heated portion of the house Makeup Air Local building codes may require the use of makeup air systems when using ventilation systems greater th...

Страница 6: ...aluminum wiring follow the procedure below 1 Connect a section of solid copper wire to the pigtail leads 2 Connect the aluminum wiring to the added section of copper wire using special connectors and...

Страница 7: ...g access hole See Step 2 for wiring hole location instructions 1 Determine and clearly mark a vertical centerline on the wall and cabinet in the area the vent opening will be made 2 To wire through to...

Страница 8: ...2 cm and a suggested maximum of 36 91 4 cm above the range to the bottom of the hood Mark a reference line on the wall 3 Using 2 or more people center the hood on the vertical centerline then align th...

Страница 9: ...e damper and the wall cap do not interfere with each other Remove the damper from the 3 x 10 8 3 x 25 4 cm rectangular vent connector if they interfere 5 Using 2 or more people lift the hood into fina...

Страница 10: ...minutes after the cooking is complete to clear all smoke and odors from the kitchen The hood controls are located on the right hand underside of the range hood Range Hood Controls Operating the light...

Страница 11: ...l grease filters as needed in a dishwasher or hand wash in a hot detergent solution to clean To Reinstall Metal Grease Filters 1 Grasp filter handles and place rear of filter into rear track 2 Push do...

Страница 12: ...12 WIRING DIAGRAM VARISTOR BK BK BK BK BK WH WH WH WH BU BK GY RD WH BU BK WH WH BU BU GY GY BK BK RD RD YL YL BR BR YL GN YL GN WH BK WH BK YL GN BK BK WH WH YL GN YL GN WH BK BU...

Страница 13: ...iances with any questions or concerns at Jenn Air Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your corresponde...

Страница 14: ...rs preservation solutions etc 5 Defects or damage caused by the use of non genuine Jenn Air parts or accessories 6 Conversion of products from natural gas or L P gas 7 Damage from accident misuse abus...

Отзывы: