 DETAILED PLANNING DIMENSIONS

4 of 4

9211AdZw817

IMPORTANT:

 Dimensional specifications are provided for planning purposes only.  

Do not make any cutouts based on this information.

 Refer to the Installation or Use & Care Guide  

before

 selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.  

All Jenn-Air

®

 appliances are appropriately UL, CUL or CSA approved.

OPENING/CLEARANCE DIMENSIONS

JF42NFXDW
42" FRENCH DOOR BOTTOM MOUNT

A

A

B

D

H

G

F

E

I

L

K

J

C

M

O

N

N

O

R

P

Q

I

H

G

F

E

110º

110º

D*

A*

B*

Floor

C*

Wall

S

BACK VIEW

FRONT VIEW

w

D

A*

F

C

C

B

E

e

Water 

Shutoff

MODEL #

JS42NXFXDE

in

cm

 A*

Width (min.)

42

106.7

B

Width of recommended electrical 
location

7

1

2

19.1

C

Distance from side of cabinet to  
recommended water connection 
location

6

15.2

D

Height (min.)

84

213.4

E

Height to recommended electrical 
location

77

195.6

F

Depth of recommended water 
connection location (max.)

1

2.5

e

Recommended electrical connection location

w

Recommended water connection location

* A minimum 2" (5.1 cm) furniture return must extend behind the face 

of the cabinet on all sides. 

ELECTRICAL REQUIREMENTS

115 volt, 60 Hz, AC only, 15- or 20-amp fused, grounded circuit is 
required. A dedicated circuit is recommended. Use an outlet that cannot 
be turned off by a switch. Do not use an extension cord.

WATER PRESSURE REQUIREMENTS

A cold water supply with water pressure between 30 and 120 psi (207 
and 827 kPa) is required to operate the ice maker. Call a licensed, 
qualified plumber with any questions about the water pressure.

Reverse Osmosis Water Supply
IMPORTANT:

 The pressure of the water coming out of a reverse osmosis 

system going to the water inlet valve of the refrigerator needs to be 
between 30 and 120 psi (207 and 827 kPa).
If a reverse osmosis water filtration system is connected to the cold water 
supply, the water pressure to the reverse osmosis system needs to be a 
minimum of 40 to 60 psi (276 to 414 kPa).

LOCATION REQUIREMENTS

Floor must be able to support refrigerator (more than 600 lb [272 kg]),  
door panels and contents of the refrigerator and must be at the same 
level as flooring in the room.

42" FULLY INTEGRATED SIDE-BY-SIDE REFRIGERATOR

(BASE UNIT REQUIRES SUITE-COORDINATING FULL HEIGHT PANEL KIT OR CUSTOM PANELS AND HANDLES)

JS42NXFXDE – 41

3

4

" x 83

1

8

" x 24"

 (without door/handles)