Jenn-Air JMW8330DAB Скачать руководство пользователя страница 2

ELECTRICAL CONNECTIONS

Unit to be properly circuit protected and wired according to
local electrical code and National Electrical Code.

It is advisable that the electrical wiring and hookup be
accomplished by a competent electrician.

120/240 VAC or 120/208 VAC 60 Hz. See serial plate on
each unit for power requirements.

The neutral of the lower unit is grounded to the frame
through the green or solid grounding wire. (The green
and the white wires are twisted together at the
termination of the conduit.) If used on new branch-circuit
installations (1996 NEC), mobile homes, recreational
vehicles, or in an area where local codes prohibit
grounding through the neutral conductor, untwist or
disconnect the green wire and connect the green wire to
ground in accordance with local code. Connect the white
neutral to the service neutral. Connect all wires to the
branch circuit with approved connectors. Use copper or
aluminum wire. If aluminum wire is used, use connectors
recognized for joining aluminum to copper.

The chart below recommends the minimum circuit
protection and wire size if the appliance is the only unit
on the circuit.

Consult a qualified electrician or serviceman if the
grounding instructions are not completely understood, or
if doubt exists as whether the appliance is properly
grounded.

SERVICE

Interrupt the source of electricity to the unit when
attempting to repair or service the oven. Failure to do
this could result in a dangerous or even fatal shock.

IMPORTANT - SAVE FOR LOCAL ELECTRICAL INSPECTOR’S USE

RECOMMENDED MINIMUM

K.W. RATING

CIRCUIT PROTECTION

WIRE SIZE

ON SERIAL PLATE

IN AMPRES

(AWG)

0 -

4.8

20

12

4.9 -

6.9

30

10

7.0 -

9.9

40

8

10.0 - 11.9

50

8

12.0 - 14.9

60

6

Improper installation of the grounding
circuit can result in a risk of electric
shock.

Содержание JMW8330DAB

Страница 1: ... Remove lower screws from hinge receptacle plates Align lower trim and reinstall screws NOTE Lower trim overlaps front edge of cabinet by 9 16 CAUTION For European style cabinets flush front the required clearance for operation of the oven door is minimum spacing of 7 8 between the cutout and the door hinge or drawer of the cabinet Some built in cabinets may not be wide enough due to their constru...

Страница 2: ...nect the white neutral to the service neutral Connect all wires to the branch circuit with approved connectors Use copper or aluminum wire If aluminum wire is used use connectors recognized for joining aluminum to copper The chart below recommends the minimum circuit protection and wire size if the appliance is the only unit on the circuit Consult a qualified electrician or serviceman if the groun...

Страница 3: ...de funcionamiento Quite los tornillos inferiores de las placas del receptáculo de la bisagra Alinee el adorno inferior y vuelva a instalar los tornillos NOTA El adorno inferior se superpone el borde de delante del gabinete por el 9 16 PRECAUCIÓN Para los gabinetes de estilo europeo con la parte delantera al ras el espacio libre requerido para el funcionamiento del horno es de cuando menos 7 8 entr...

Страница 4: ... de servicio Conecte todos los alambres al circuito de derivación con conectores aprobados Use alambre de cobre o aluminio Si se usa alambre de aluminio use los conectores indicados para unir aluminio a cobre La tabla a continuación muestra la mínima protección del circuito y el tamaño de alambre recomendados si el electrodoméstico es la única unidad en el circuito Consulte con un electricista o t...

Страница 5: ...nement du four dans le Manuel de l utilisateur Enlever les vis inférieures des plaques de charnière Aligner la garniture inférieure et remettre les vis REMARQUE La garniture inférieure recouvre le bord avant de l armoire de 9 16 po ATTENTION Dans le cas d armoires de style européen à façade intégrée le dégagement nécessaire pour permettre d ouvrir la porte du four est d un minimum de 7 8 po entre ...

Страница 6: ...accorder tous les fils au circuit de dérivation avec des connecteurs homologués Utiliser du fil de cuivre ou d aluminium En cas d utilisation de fil d aluminium utiliser les connecteurs conçus pour raccorder de l aluminium au cuivre Le tableau ci dessous recommande la protection des circuits et le calibre de câble minimum lorsque l appareil est le seul branché sur le circuit Consulter un électrici...

Отзывы: