Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing  
any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.

JENN-AIR

®

 DETAILED PLANNING DIMENSIONS

2 of 4

JRC120060A  07/2012  

OPENING/cLEARANcE DIMENSIONS

FRONT VIEW 

e

A

C

B

D

Side

Cabinet

E

Mounting Plate

MODEL #

JMV9186W 
JMV8208W

in

cm

A

Width of cabinet opening (min.)

30

76.2

B

Height from cooking surface  
to floor

C

Suggested distance from  
top of cabinet opening to  
cooking surface

30

76.2

D

Height from floor to top of cabinet 
opening (B + C = D)

E

Depth of upper cabinet (min.-max.)

12-14

30.5-

35.6

e

Recommended electrical connection location

OvER-ThE-RANGE MIcROwAvE OvENS

JMV9186W, JMV8208W – 29

7

8

" x 17

1

4

" x 17

1

2

"

SIDE VIEW

BACK VIEW

ELECTRICAL REQUIREMENTS

120 volt, 60 Hz, AC only, 15- or 20-amp fused, electrical supply 
is required. A time-delay fuse or dedicated circuit is recommended.  
Do not use an extension cord.

VENTING REQUIREMENTS 

The microwave oven is factory set for recirculating ventilation. 
To vent through the roof or wall, refer to installation instructions  
for further information.

LOCATION REQUIREMENTS 

Support structure must be able to support 150 lb (68 kg) including  
microwave oven and upper cabinet including contents. 
Mounting plate must attach to a minimum of one 2" x 4"  
(5.1 cm x 10.2 cm) wall stud. 
Minimum distance between a fixed wall on the hinged-side  
of the door and the microwave oven is 6" (15.2 cm).

e

A

C

B

D

Side

Cabinet

E

Mounting Plate

e

A

C

B

D

Side

Cabinet

E

Mounting Plate