24” (61.00 CM) STANDARD MOUNT

Cabinet Preparation

Cabinet Dimensions

B

C

D

E

F

G

H

I

I

J

K

N

L

M

A

A. 6

 (152.40 mm) minimum 

16

 (406.40 mm) maximum

B. Suggested electrical recepticle 

location

C. Anti-Tip block
D. 3

"

 (76.20 mm)

E. 3

1

/

2

"

 (88.90 mm)

F. 4.5

"

 (114.30 mm)

G. 22

1

/

8

 (614.35 mm) opening

H. 14

13

/

16

 (376.24 mm) to bottom  

of Anti-Tip block

I. Allow 

7

/

8

 (22.23 mm) overlap

J. 24

"

 (609.60 mm) minimum depth

K. Allow 

9

/

16

 (5.62 mm)

L. Platform must support 100 lb 

(45.4 kg)

M. 15

9

/

16

 (395.27 mm) opening

N. Allow 

3

/

4

 (19.05 mm) overlap

O. 1

17

/

32

 (39 mm)

Top view 

G

O

Anti-Tip block

Drawer

face

Cabinet

face

Содержание JMDFS24GS

Страница 1: ...ts 3 Location Requirements 3 Minimum Dimensions 3 Electrical Requirements 4 24 61 00 CM STANDARD MOUNT 5 Cabinet Preparation 5 24 61 00 CM FLUSH MOUNT 6 Cabinet Preparation 6 INSTALLATION INSTRUCTIONS...

Страница 2: ...2 MICROWAVE DRAWER SAFETY...

Страница 3: ...itable for use below cooktops The Microwave Drawer may be located in a cabinet or below the counter and or below a built in oven Check the opening where the Microwave Drawer will be installed The loca...

Страница 4: ...ding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WARNING Improper use of the grounding plug can result in a risk of electric shock Consul...

Страница 5: ...on C Anti Tip block D 3 76 20 mm E 31 2 88 90 mm F 4 5 114 30 mm G 221 8 614 35 mm opening H 1413 16 376 24 mm to bottom of Anti Tip block I Allow 7 8 22 23 mm overlap J 24 609 60 mm minimum depth K A...

Страница 6: ...16 406 40 mm maximum B Suggested electrical recepticle location C Anti Tip block D 3 76 20 mm E 31 2 88 90 mm F 4 5 114 30 mm G 243 16 614 35 mm minimum H 1413 16 376 24 mm to bottom of Anti Tip bloc...

Страница 7: ...floor Install the Microwave Drawer 1 Empty Microwave Drawer of any loose contents 2 Using two or more people slide Microwave Drawer all the way into the opening and center the Microwave Drawer 3 Open...

Страница 8: ...tion of Microwave Drawer by placing 1 cup 250 mL of water in the Microwave Drawer and programming cook time of 1 minute at 100 power 2 If the Microwave Drawer does not operate Check that a household f...

Страница 9: ...cas de non respect des instructions Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez v...

Страница 10: ...un comptoir ou sous un four encastr Inspecter l ouverture o le tiroir micro ondes sera install Il doit comporter les caract ristiques suivantes IMPORTANT Observer les dispositions de tous les codes e...

Страница 11: ...appropri e du conducteur de liaison la terre peut causer un risque de choc lectrique Consulter un lectricien ou un technicien qualifi si les instructions de mise la terre ne sont pas compl tement comp...

Страница 12: ...88 90 mm F 4 5 po 114 30 mm G Ouverture de 221 8 po 614 35 mm H 1413 16 po 376 24 mm au bas de la cale de bride antibasculement I Permettre un chevauchement de 7 8 po 22 23 mm J Profondeur minimale d...

Страница 13: ...B Emplacement sugg r de la prise lectrique C Cale de bride antibasculement D 3 po 76 20 mm E 31 2 po 88 90 mm F 4 5 po 114 30 mm G Minimum de 243 16 po 614 35 mm H 1413 16 po 376 24 mm au bas de la ca...

Страница 14: ...ble La partie inf rieure de la cale doit se trouver 14 13 16 po 37 6 cm de l ouverture d coup e au plancher Installation du tiroir micro ondes 1 Vider le tiroir micro ondes de tout article 2 l aide d...

Страница 15: ...r le contact avec les c t s de l ouverture d coup e et viter de pincer le cordon entre le four et le mur 5 Glisser le tiroir jusqu au fond jusqu ce que les rebords de montage touchent les tasseaux mon...

Страница 16: ...fier que le cordon d alimentation est correctement branch sur une prise reli e la terre Pour l information relative au d pannage consulter le Guide d utilisation et d entretien L installation est main...

Отзывы: