JENN-AIR

®

 DETAILED PLANNING DIMENSIONS

3 of 5

8611AdZw915

IMPORTANT:

 Dimensional specifications are provided for planning purposes only.  

Do not make any cutouts based on this information.

 Refer to the Installation Guide 

before

 

selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.  
All Jenn-Air

®

 appliances are appropriately UL, CUL or CSA approved.

A

D

E

B C

F

G

H

A

J

K

L

M

I

I

B

G

A

I

J

E

F

H

Power Supply Location

C

D

g

g

A

B

C*

A

B

C*

G

G

e

e

e

e

A

B

C

e

e

E

D

D

D

F

E

F

E

F

B

C*

e

e

J

A

I

H

g

g

A

B

C*

A

B

C*

G

G

e

e

e

e

A

B

C

e

e

E

D

D

D

F

E

F

E

F

B

C*

e

e

J

A

I

H

g

g

A

B

C*

A

B

C*

G

G

e

e

e

e

A

B

C

e

e

E

D

D

D

F

E

F

E

F

B

C*

e

e

J

A

I

H

OPENING/CLEARANCE DIMENSIONS

FRONT VIEW

SIDE VIEW

UNDER COUNTER INSTALLATION 

(without cooktop installed above)  

BACK VIEW

30" SINGLE WALL OVENS

JJW3430D, JJW2430D – 30" x 29

7

8

" x 25

5

16

"

MODEL #

JJW3430D 
JJW2430D

in

cm

A

Width of cabinet (min.)

30

76.2

B

Width of cutout

28

1

2

72.4

 C*

Height of cutout 
(recommended)

28

71.2

D

Top of cutout to bottom  
of upper cabinet door (min.)

2

3

16

5.5

E

Bottom of cutout to top  
of lower cabinet door (min.)

1

1

2

3.8

F

Bottom of cutout to floor 

32

81.3

G

Depth of cutout (min.)

24

61.0

H

Top of countertop to bottom 
of cutout (min.)

30

3

16

76.7

I

Top of cutout to underside of 
countertop (min.)

1

1

2

3.8

J

Bottom of cutout to floor 

4

5

16

11.0

e

Recommended junction box location

*Will fit cutout height from 26

15

16

" (68.4 cm) to 29

7

16

" (74.8 cm).

ELECTRICAL REQUIREMENTS

240 volt, 20-amp fused, grounded circuit is required. A dedicated 
circuit is required.
The length of conduit provided is for serviceability. Do not cut 
the conduit. The junction box should be located 3" (7.6 cm) 
maximum below the support surface. Drill a 1" (2.5 cm) 
minimum diameter hole in the right rear or left rear corner of 
the support surface for access to the junction box.

NOTE:

 For under counter installation, the junction box should be  

located in the adjacent right or left cabinet. Drill a 1" (2.5 cm) 
minimum diameter hole in an upper corner of the side wall for 
access to the junction box.

CABINET REQUIREMENTS

NOTE:

 When using under counter installation, check cabinet 

manufacturer’s specifications to verify fit.