Venting Methods

Common venting methods are shown for a counter-mounted 
downdraft cooktop. The cooktop may be vented through the wall 
or floor. 

Concrete Slab Installations - Exhaust Through Wall

Jenn-Air

®

 Duct Free Filter Accessory Kit

(For model numbers JED3430, JED3536, JED4430, JED4536, 
JGD3430 and JGD3536)

On select downdraft models, the Jenn-Air

®

 Duct Free Filter 

Accessory Kit Part Number JDA7000WX is now available. The 
Jenn-Air

®

 Duct Free Filter Accessory Kit is ideal for both new 

construction and kitchen renovation projects because it provides 
an easy alternative to the installation of metal ducting and venting 
in the downdraft system outside the home. The kit includes all 
required hardware, one filter and complete installation 
instructions. For more information on the Jenn-Air

® 

Duct Free 

Filter Accessory Kit, contact your Jenn-Air dealer or call 
1-800-JENNAIR (1-800-536-6247).

Option 1 - Roof Venting

Option 2 - Wall Venting

A. Roof cap
B. 6" (15.2 cm) round roof venting

A. 6" (15.2 cm) round wall venting
B. Wall cap

Option 3 - Venting Between 

Floor Joist

Option 4 - Venting behind 

Cabinet Kick Plate

A. Wall cap
B. 6" (15.2 cm) round wall venting

A. Wall cap
B. 6" (15.2 cm) round wall venting

A

B

A

B

A

B

A

B

A. Wall cap
B. 6" (15.2 cm) round metal vent

C. 16" (40.6 cm) maximum
D. 6" (15.2 cm) round PVC sewer pipe

E. 6" (15.2 cm) round metal vent

F. 6" (15.2 cm) round PVC coupling

G. Concrete slab
H. 6" (15.2 cm) round PVC sewer pipe

I. 6" (15.2 cm) round 90° PVC sewer pipe elbow

J. Tightly pack gravel or sand completely around pipe.

K. 30 ft (9.1 m) max.

L. 6" (15.2 cm) round 90° PVC sewer pipe elbow

M. 6" (15.2 cm) round PVC coupling

N. 12" (30.5 cm) minimum

 

 

 

 

 

 

A

B

C

D

E

F

G

H

I

J

L

K

Содержание JGD3430WB

Страница 1: ...ccordement au gaz 22 Syst me d allumage lectronique 24 Achever l installation 24 You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t fol...

Страница 2: ...er WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detect...

Страница 3: ...clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section The cooktop is designed to han...

Страница 4: ...I C A B A B D C E F I G H A 30 76 2 cm on 30 76 2 cm models 36 91 4 cm on 36 91 4 cm models B Combustible area above countertop shown by dashed box above C 30 76 2 cm minimum clearance between top of...

Страница 5: ...d Elbows too close together can cause excess turbulence that reduces airflow Do not use a 5 12 7 cm elbow in a 6 15 2 cm or 3 x 10 8 3 x 25 4 cm system Do not reduce to a 5 12 7 cm system after using...

Страница 6: ...lete installation instructions For more information on the Jenn Air Duct Free Filter Accessory Kit contact your Jenn Air dealer or call 1 800 JENNAIR 1 800 536 6247 Option 1 Roof Venting Option 2 Wall...

Страница 7: ...d Ohio 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a separate circuit serving only t...

Страница 8: ...el tubing gas connector designed by CSA to connect the cooktop to the rigid gas supply line A male pipe thread is needed for connection to the female pipe threads of the inlet to the cooktop pressure...

Страница 9: ...ower Optional section 5 Using 2 or more people remove the cooktop from the carton REMEMBER An undercounter built in oven cannot be installed under this cooktop 6 Place cooktop right side up into the c...

Страница 10: ...ollow steps 5 10 in the Install Cooktop section MakeGasConnection 1 Apply pipe joint compound made for use with Natural and LP gas to the smaller thread ends of the flexible connector adapters see C a...

Страница 11: ...indicated Correct any leak found 3 Remove surface burner caps and grates from parts package Align notches in burner caps with pins in burner base Burner caps should be level when properly positioned...

Страница 12: ...fference between the ports will be noticeable when the burner is used or when adjustments are made to the flame length Adjust the height of top burner flames The cooktop low burner flame should be a s...

Страница 13: ...u un d c s Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE...

Страница 14: ...la table de cuisson doivent tre scell es Respecter les dimensions indiqu es pour les ouvertures d couper dans les placards Ces dimensions constituent les valeurs minimales des d gagements de s parati...

Страница 15: ...40 ou des codes locaux en vigueur Dimensions du produit Table de cuisson de 30 76 2 cm Table de cuisson de 36 91 4 cm A 21 54 6 cm B 19 50 0 cm C Emplacement de la plaque signal tique A 30 76 2 cm B 1...

Страница 16: ...les mod les de 30 76 2 cm 36 91 4 cm sur les mod les de 36 91 4 cm B Zone de mati re combustible au dessus du plan de travail espace d limit par des lignes pointill es ci dessus C Distance minimale d...

Страница 17: ...r ou le toit La longueur du syst me d vacuation et le nombre de coudes doit tre r duit au minimum pour une performance efficace La longueur maximale quivalente du circuit d vacuation est de 60 pi 18 3...

Страница 18: ...oi d un conduit flexible Un conduit flexible peut causer une r tro pression et des turbulences de l air ce qui r duit consid rablement la performance A Bouche de d charge murale B Conduit m tallique d...

Страница 19: ...codes et r glements locaux En l absence de code local l installation doit satisfaire aux prescriptions de la plus r cente dition du code national am ricain en vigueur National Fuel Gas Code ANSI Z223...

Страница 20: ...e n cessite pas le d montage de la table de cuisson pour les man uvres d ouverture fermeture Ne pas entraver l acc s au robinet d arr t manuel Le robinet d arr t manuel est pr vu pour ouvrir ou fermer...

Страница 21: ...vantes doivent tre ex cut es si le produit est install avec une configuration d b nisterie en p ninsule ou en lot La volute d vacuation est mont e l usine de mani re ce que le syst me d vacuation soit...

Страница 22: ...isation avec du gaz naturel ou du gaz propane sur l extr mit filet e la plus petite des adaptateurs de raccord flexible voir C et G dans l illustration suivante 2 Fixer un raccord d adaptation sur le...

Страница 23: ...face et les grilles du sachet de pi ces Aligner les encoches des chapeaux de br leur avec les broches dans la base de chaque br leur Un chapeau de br leur correctement plac doit tre horizontal Si le c...

Страница 24: ...e cuisson Pour le r glage au d bit thermique minimum on doit observer des flammes stables bleues d environ 0 64 cm R glage des br leurs standard La vis de r glage au centre de la tige de commande du r...

Отзывы: