background image

5

Electrical Requirements

IMPORTANT:

 The cooktop must be electrically grounded in 

accordance with local codes and ordinances, or in the absence 

of local codes, with the National Electrical Code, ANSI/NFPA 70 

or Canadian Electrical Code, CSA C22.1.
This cooktop is equipped with an electronic ignition system 

that will not operate if plugged into an outlet that is not properly 

polarized.
This cooktop is equipped with an electronic ignition system that 

will not operate properly if plugged into a ground fault interrupt 

circuit.
If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrical installer determine 

that the ground path is adequate.
A copy of the above code standards can be obtained from:

National Fire Protection Association 

1 Batterymarch Park 

Quincy, MA 02169-7471

CSA International 

8501 East Pleasant Valley Road 

Cleveland, OH 44131-5575

 

Electronic ignition systems operate within wide voltage limits, 

but proper grounding and polarity are necessary. Check that 

the outlet provides 120-volt power and is correctly grounded.

 

This gas cooktop is not required to be plugged into a GFCI 

(Ground-Fault Circuit Interrupter) outlet or AFCI (Arc Fault 

Circuit Interrupter) type circuit breaker. It is recommended 

that you not plug an electric spark ignition gas cooktop or 

any other major appliance into a GFCI wall outlet or a AFCI  

breaker as it may cause these types of circuit breaker to trip 

during normal cycling.

 

Performance of this cooktop will not be affected if operated 

on a GFCI/AFCI-protected circuit. However, occasional 

nuisance tripping of the GFCI/AFCI breaker is possible due 

to the normal operating nature of electronic gas cooktops.

 

The wiring diagram is provided with this cooktop. It is 

located inside the cooktop burner box.

Gas Supply Requirements

Observe all governing codes and ordinances.

IMPORTANT:

 This installation must conform with all local codes 

and ordinances. In the absence of local codes, installation must 

conform with American National Standard, National Fuel Gas 

Code ANSI Z223.1—latest edition or CAN/CGA B149—latest 

edition.

IMPORTANT:

 Leak testing of the cooktop must be conducted 

according to the manufacturer’s instructions.

Type of Gas

Natural Gas:

This cooktop is factory-set for use with Natural gas. To convert 

to Propane gas, see the Gas Conversion instructions provided 

in the package containing the literature. The model/serial/rating 

plate located on the underside of the burner box has information 

on the types of gas that can be used. If the types of gas listed 

do not include the type of gas available, check with the local 

gas supplier.

Propane Gas conversion:

Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas 

specified on the model/serial/rating plate for use with a different 

gas without consulting the serving gas supplier. See the Gas 

Conversion instructions provided in the package containing 

the literature.

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make 

sure gas pressure does not exceed 14" (36 cm) water 

column. 
Examples of a qualified person include: 
licensed heating personnel, 

authorized gas company personnel, and

authorized service personnel.
Failure to do so can result in death, explosion, or fire.

Содержание JGC3215GS

Страница 1: ...ur référence ultérieure COOKTOP SAFETY 1 INSTALLATION REQUIREMENTS 3 Tools and Parts 3 Location Requirements 3 Electrical Requirements 5 Gas Supply Requirements 5 INSTALLATION INSTRUCTIONS 7 Prepare Cooktop for Installation 7 Install Cooktop 7 Make Gas Connection 8 Complete Installation 9 SÉCURITÉ DE LA TABLE DE CUISSON 11 EXIGENCES D INSTALLATION 12 Outillage et pièces 12 Exigences d emplacement ...

Страница 2: ...s cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions IMPORTANT Do not install a ventilation system that blows air downward toward this gas cooking appliance This type of ventilation system may cause ignition and combu...

Страница 3: ...or floor where cooktop is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances Grounded and polarized electrical supply is required See the Electrical Requirements section Proper gas supply connection must be available See the Gas Supply Requirements section The gas and electric supply should be located as shown in Gas and El...

Страница 4: ... not recommended for countertops with a molded backsplash Do not silicone seal in place Multi Unit Flush Dimensions Units Recessed Area Width D Cutout Width C One 15 38 1 cm unit 151 8 38 4 cm 143 8 36 5 cm Two 15 38 1 cm units 301 8 76 5 cm 293 8 74 6 cm Three 15 38 1 cm units 451 8 114 6 cm 447 16 112 9 cm Four 15 38 1 cm units 601 8 152 7 cm 597 16 151 0 cm 30 76 2 cm cooktop and one 15 38 1 cm...

Страница 5: ...I breaker is possible due to the normal operating nature of electronic gas cooktops The wiring diagram is provided with this cooktop It is located inside the cooktop burner box Gas Supply Requirements Observe all governing codes and ordinances IMPORTANT This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National ...

Страница 6: ... pressure to the regulator should be as follows for proper operation Natural Gas Minimum pressure 15 2 cm WCP Maximum pressure 35 5 cm WCP Propane Gas Minimum pressure 27 9 cm WCP Maximum pressure 35 5 cm WCP Contact local gas supplier if you are not sure about the inlet pressure NOTE For multi unit installations each unit must have its own regulator supplied with the unit Burner Input Requirement...

Страница 7: ...ktop sit flat on uneven countertops Do not silicone seal in place Install Cooktop Install the pressure regulator to the cooktop before installing the cooktop See the Make Gas Connections section Multi unit installation For multi unit installations a mounting bridge kit is required See the Tools and Parts section Cooktop over built in oven IMPORTANT Clamping brackets should not be used 1 Install th...

Страница 8: ...dapters see B and F in the following illustration 2 Attach one adapter to the gas pressure regulator and the other adapter to the gas shut off valve Tighten both adapters 3 Use a 15 16 2 4 cm combination wrench and channel lock pliers to attach the flexible connector to the adapters Check that connector is not kinked No appliance obstructions below cooktop Suggested installation to avoid interfere...

Страница 9: ...ace Burners 1 Push in and turn the surface burner control knobs to IGNITE The surface burner flame should light within 4 seconds The first time a surface burner is lit it may take longer than 4 seconds to light because of air in the gas line 2 Turn the control knob to HI and check for a blue colored flame It should be clean and soft in character No yellow tip blowing or lifting of flame should occ...

Страница 10: ...10 Notes ...

Страница 11: ...indre votre fournisseur de gaz appeler les pompiers L installation et l entretien doivent être effectués par un installateur qualifié une agence de service ou le fournisseur de gaz AVERTISSEMENT L odorat ne permet pas toujours la détection d une fuite de gaz Les distributeurs de gaz recommandent l emploi d un détecteur de gaz homologation UL ou CSA Pour d autre information contacter le fournisseur...

Страница 12: ... cuisson doit être installée dans un emplacement à l écart des zones de forts courants d air telles que fenêtres portes et évents ou ventilateurs de chauffage Toutes les ouvertures dans le mur ou le plancher de l emplacement d installation de la table de cuisson doivent être scellées Respecter les dimensions indiquées pour les ouvertures à découper dans les meubles Ces dimensions constituent les v...

Страница 13: ... 74 6 cm Trois unités de 15 38 1 cm 45 114 3 cm 447 16 112 9 cm Quatre unités de 15 38 1 cm 60 152 4 cm 597 16 151 0 cm Table de cuisson 30 76 2 cm et une unité de 15 38 1 cm 45 114 3 cm 443 8 112 7 cm Table de cuisson 30 76 2 cm et deux unités de 15 38 1 cm 60 152 4 cm 597 16 151 0 cm Table de cuisson 36 91 4 cm et une unité de 15 38 1 cm 51 129 5 cm 503 8 128 0 cm A B C D A Détenteur fourni flèc...

Страница 14: ...I NFPA 70 ou le Code canadien des installations électriques CSA C22 1 Cette table de cuisson est dotée d un système d allumage électronique qui ne fonctionnera pas en cas de branchement dans une prise qui n est pas correctement polarisée Cette table de cuisson est dotée d un système d allumage électronique qui ne fonctionnera pas en cas de branchement sur un circuit avec disjoncteur de fuite à la ...

Страница 15: ... en acier inoxydable de 5 8 1 6 cm conçu par CSA pour raccorder la table de cuisson à la canalisation rigide d alimentation en gaz REMARQUE Dans le cas d installations multiples une seule vanne de fermeture est requise Chaque unité doit disposer de son propre régulateur fourni avec l unité et un connecteur pour le gaz en acier inoxydable flexible Un raccord avec filetage mâle de 1 2 1 3 cm est néc...

Страница 16: ...tirer l endos de la bande de mousse Pour les installations sur le comptoir Appliquer le côté adhésif de la bande de mousse sur le plan de travail à 1 16 1 6 mm près des bords de l ouverture avant arrière et côtés Pour les installations affleurantes Appliquer le côté adhésif de la bande de mousse sur le bas de l ouverture en retrait Conserver l excédent de bande de mousse aux fins d utilisation ave...

Страница 17: ...on du gaz et l autre raccord d adaptation sur le robinet d arrêt de la canalisation de gaz Serrer les deux adaptateurs 3 Utiliser une clé mixte de 15 16 2 4 cm et une pince multiprise pour fixer le raccord flexible sur les raccords d adaptation S assurer que le raccord n est pas déformé Il ne doit pas y avoir d appareil ou d obstacle endessous de la table de cuisson Configuration d installation su...

Страница 18: ...foncer et tourner les boutons de commande de brûleur de surface à IGNITE allumage Le gaz doit s enflammer sur le brûleur de surface en moins de 4 secondes Lors de l allumage initial du brûleur de surface le délai d allumage peut être supérieur à 4 secondes du fait de la présence d air dans la canalisation de gaz 2 Tourner le bouton de commande à la position HI élevée et vérifier que la flamme est ...

Страница 19: ...19 Notes ...

Страница 20: ...W11030506B 2017 Jenn Air Used under license in Canada All rights reserved Utilisé sous licence au Canada Tous droits réservés 03 17 ...