7
Convert from LP Gas to Natural Gas
1.
Turn manual shutoff valve to the closed position.
2.
Unplug cooktop, or disconnect power.
To Convert Gas Pressure Regulator
3.
Determine the type of regulator you have:
Style 1:
The cap has a slot and “LP” printed on it.
Remove access cap by using a flat-blade screwdriver
or coin, turning the access cap counterclockwise.
The gas pressure regulator has 2 settings which are
stamped on either side of the cap. Turn the cap and
reinstall into regulator with the stamp “NAT” visible
from the outside of the regulator.
Style 2:
The cap does not have a slot and requires
a wrench to be removed.
Remove the access cap by using a wrench, turning
the access cap counterclockwise.
Remove spring retainer from the cap by pushing against
the flat side of the spring retainer. Look at the spring
retainer to locate the “LP” or “NAT” position. Turn over
the spring retainer so the “NAT” is showing on the bottom.
Snap the spring retainer back into the cap. Reinstall the
cap onto the regulator.
4.
If they are installed, remove the burner grates.
Use the following chart to match the correct gas orifice spud
with the burner location and model being converted.
Natural Gas Orifice Spud Chart
Burner Rating
Stamp (A)
Size
1,300 BTU*
53
0.53 mm
A
6,000 BTU
110
1.10 mm
9,050 BTU
132
1.32 mm
12,000 BTU
155
1.55 mm
18,000 BTU
190
1.90 mm
A. Size stamp
*Simmer orifice for the dual stack (center) burner.
Burner Models
Model No.
Right
front
Right
rear
Center
Left
front
Left
rear
JGC2530E
6,000
BTU
12,000
BTU
18,000
BTU
9,050
BTU
12,000
BTU
JGC2536E
6,000
BTU
12,000
BTU
18,000
BTU
9,050
BTU
12,000
BTU
A
B
C
A. To cooktop
B. Shutoff valve (closed position)
C. Gas supply line
A
B
C
D
A. Access cap
B. Rear of cooktop
C. Gas pressure regulator
D. Gas flow
NAT
A
B
C
D
E
A. Access cap
B. Gasket
C. Gas pressure regulator
D. NAT position
E. LP position