5
6. Remove all burner caps and burner bases. Be sure to keep
the cap and base for each burner together. This will assure
that the cap and base are reinstalled on the proper burner.
7. To convert burners:
■
Insert
7
.0 mm nut driver down onto the gas orifice spud
(C) and remove by turning it counterclockwise and lifting
out.
■
Set gas orifice spud aside.
■
Replace with correct LP gas orifice spud. See the LP Gas
Orifice Spud Chart.
IMPORTANT: Place Natural gas orifice spuds in plastic parts
bag for future use and keep with package containing
literature.
8. Replace burner bases and burner caps.
IMPORTANT: Be sure that the electrode aligns with the notch
or hole in the burner base. The igniter electrode is ceramic
and could break during installation of the burner base.
9. Open shutoff valve in the gas supply line. The valve is open
when the handle is parallel to the gas pipe.
10. Once you have completed converting all of the cooktop
burners, test the cooktop for leaks by brushing on an
approved noncorrosive leak-detection solution. If bubbles
appear, a leak is indicated. Correct any leaks found.
11. Plug in cooktop or reconnect power.
12. Adjust valve according to “Low Flame Height Adjustment”
section.
A. Gas tube opening
B. Burner cap
C. Burner base
D. Orifice holder
E. Igniter electrode
F. Burner base notch
or hole
Standard and
simmer burners
A. Igniter electrode
B. Orifice holder
C. Orifice spud
Dual flame burner
A. Igniter electrode
B. Orifice holder
C. Orifice spud
D. Orifice simmer
A
B
C
D
E
F
A
B
C
A
C
B
D
A. Burner cap
B. Electrode
C. Burner base
A
B
C
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Содержание JGC1530B Series