A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA
�
Check with a qualified electrical installer if you are not sure the
range is properly grounded.
Range Rating*
Specified Rating of
Power Supply Cord
Kit and Circuit
Protection
120/240 V
120/208 V
Ampere
8.8-16.5 kW
7.8-12.5 kW
40 or 50**
16.6-22.5 kW
12.6-18.5 kW
50
*The NEC calculated load is less than the total connected load
listed on the model/serial/rating plate.
**If connecting to a 50 A circuit, use a 50 A rated cord with kit.
For 50 A rated cord kits, use kits that specify use with a
nominal 1
3
/
8
" (34.9 mm) diameter connection opening.
�
When a 4-wire, single phase 250 V, 60 Hz, AC-only electrical
supply is available, a 40 A minimum circuit protection is
required on 30" (76.2 cm) ranges, fused on both sides of the
line.
�
A circuit breaker is recommended.
�
This range is equipped with a UL or CSA International Certified
Power Cord intended to be plugged into a standard 14-50R
wall receptacle. Be sure the wall receptacle is within reach of
range’s final location.
�
Do not use an extension cord.
INSTALLATION
Unpack Range
WARNING
Excessive Weight Hazard
Use two or more people to move and install or uninstall
appliance.
Failure to do so can result in back or other injury.
1.
Remove shipping materials, tape and film from the range.
Keep cardboard bottom under range. Do not dispose of
anything until the installation is complete.
2.
Remove oven racks and parts package from oven and
shipping materials.
3.
To remove cardboard bottom, first take 4 cardboard corners
from the carton. Stack one cardboard corner on top of
another. Repeat with the other 2 corners. Place them
lengthwise on the floor behind the range to support the range
when it is laid on its back.
4.
Using 2 or more people, firmly grasp the range and gently lay
it on its back on the cardboard corners.
5.
Remove cardboard bottom.
The leveling legs can be adjusted while the range is on its
back. See the “Adjust Leveling Legs” section.
NOTE:
To place range back up into a standing position, put a
sheet of cardboard or hardboard on the floor in front of range
to protect the flooring. Using 2 or more people, stand range
back up onto the cardboard or hardboard.
Install Anti-Tip Bracket
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation
instructions.
Slide range back so rear range foot is engaged in the
slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed
and engaged.
Failure to follow these instructions can result in death or
serious burns to children and adults.
1.
Remove the anti-tip bracket from the inside of the oven.
2.
Determine which mounting method to use: floor or wall.
If you have a stone or masonry floor, you can use the wall
mounting method. If you are installing the range in a mobile
home, you must secure the range to the floor.
This anti-tip bracket and screws can be used with wood or
metal studs.
3.
Determine and mark centerline of the cutout space. The
mounting can be installed on either the left-side or right-side of
the cutout. Position mounting bracket against the wall in the
cutout so that the V-notch of the bracket is 12
1
/
2
" (31.8 cm)
from centerline as shown.
C
B
A
A.
12
1
/
2
" (31.8 cm)
B.
Bracket V-notch
C.
Centerline