background image

3

Product Dimensions

*Serial number plate may be rotated up from behind the control 

panel for viewing from the front of the range.

**Excludes handle. Dimension given is from wall to front of oven 

door and will vary based on electric outlet receptacle 
installation.

Cabinet Dimensions

Cabinet opening dimensions shown are for 25" (64 cm) 
countertop depth, 24" (61 cm) base cabinet depth and 
36" (91.4 cm) countertop height.

If installing a range hood or microwave hood combination above 
the range, follow the range hood or microwave hood combination 
installation instructions for dimensional clearances above the 
cooktop surface.

A freestanding range may be installed next to combustible walls 
with zero clearance.

NOTE: 24" (61 cm) minimum when bottom of wood or metal 
cabinet is protected by not less than 

¹⁄₄

" (0.64 cm) flame retardant 

millboard covered with not less than No. 28 MSG sheet steel, 
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 
0.020" (0.5 mm) copper.

30" (76.2 cm) minimum clearance between the top of the cooking 
platform and the bottom of an unprotected wood or metal 
cabinet.

A.

46⁷⁄₈

" (119.9 cm)

B. Model/serial number plate 

(located behind the control 
panel)*

C.

35⁷⁄₈

" (91.4 cm) 

D. 29

⁷⁄₈

" (75.9 cm)

E. 26

⁵⁄₁₆

" - 27¼" (66.8 - 69.2 cm)** 

A

E*

D

C

B

A. 13" (33 cm) upper cabinet 

depth

B. 30" (76.2 cm) min. opening 

width

C. For minimum clearance to the 

top of the cooktop,
see NOTE.

D. 30" (76.2 cm) min. opening 

width

E. Cabinet door or hinge should 

not extend into cutout.

F. 3-wire shaded area* - 

7" (17.8 cm) min. from left 
side cabinet,  5¾" (14.6 cm) 
max. from floor, 6" (15.2 cm) 
max. width

G. 4-wire shaded area* - 

10" (25.4 cm) min. from right 
side cabinet,  5¾" (14.6 cm) 
max. from floor, 6" (15.2 cm) 
max. width
*Nothing located in shaded 
 areas can extend more than 
 1½" (3.8 cm) from wall or 
 range will not slide all the way
 back.

H. 1½" (3.8 cm) min. from floor if 

using a flush mount outlet.

A

B

D

F

E

C

G

H

Содержание JER8895BAS - 30" Electric Double Oven Range

Страница 1: ...injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury a...

Страница 2: ...that projects horizontally a minimum of 5 12 7 cm beyond the bottom of the cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum clearances The floor anti tip b...

Страница 3: ...retardant millboard covered with not less than No 28 MSG sheet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance between the top of the cooki...

Страница 4: ...r circuit breaker box through flexible or nonmetallic sheathed copper or aluminum cable See Electrical Connection Allow 2 to 3 ft 61 0 cm to 91 4 cm of slack in the line so that the range can be moved...

Страница 5: ...maximum of 1 2 5 cm A minimum of 5 mm is needed to engage the anti tip bracket NOTE If height adjustment is made when range is standing tilt the range back to adjust the front legs then tilt forward...

Страница 6: ...n and toward you to remove cover 3 Remove plastic tag holding three 10 32 hex nuts from the middle post of the terminal block A 12 x 1 screws B Anti tip bracket A B A 12 x 1 screws B Anti tip bracket...

Страница 7: ...nduit plate down and out Position cord conduit plate as shown in the following illustration Replace cord conduit plate and insert screws Assemble a UL listed conduit connector in the opening Feed the...

Страница 8: ...rminal block posts with 10 32 hex nuts 7 Securely tighten hex nuts NOTE For power supply cord replacement only use a power cord rated at 250 volts minimum 40 amps or 50 amps that is marked for use wit...

Страница 9: ...nnected directly to the fuse disconnect or circuit breaker box Depending on your electrical supply make the required 3 wire or 4 wire connection 1 Strip outer covering back 3 7 6 cm to expose wires St...

Страница 10: ...s 7 Connect line 1 black and line 2 red wires to the outer terminal block posts with 10 32 hex nuts 8 Securely tighten hex nuts 9 Replace terminal block access cover 3 wire connection Direct Wire Use...

Страница 11: ...for satisfactory baking conditions CompleteInstallation 1 Check that all parts are now installed If there is an extra part go back through the steps to see which step was skipped 2 Check that you have...

Страница 12: ...nge forward 3 Complete cleaning or maintenance 4 Check that anti tip bracket is installed Look for the anti tip bracket securely attached to floor or wall Slide range back so rear range foot is under...

Отзывы: