background image

JENN-AIR® DETAILED PLANNING DIMENSIONS

4 of 4

8557AdZw815

IMPORTANT:

 Dimensional specifications are provided for planning purposes only.  

Do not make any cutouts based on this information.

 Refer to the Installation or Use & Care Guide  

before

 selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.  

All Jenn-Air

®

 appliances are appropriately UL, CUL or CSA approved.

DOWNDRAFT COOKTOP DUCTING ARRANGEMENTS

The diagrams below show typical duct arrangements for downdraft cooktops. JX3™ downdraft cooktops  
also offer a duct-free installation option. For more details, refer to page 3.

Roof jack

Transition elbow 

3

1

4

" x 10" 

(8.3 cm x 25.4 cm) duct – 

54' (16.5 m) max. 

REAR DUCTING THROUGH WALL TO OUTSIDE

REAR DUCTING IN WALL TO ROOF

DUCTING CONFIGURATIONS

CALCULATING MAXIMUM DUCTING LENGTH

•  Maximum ducting length is 60' (18.3 m).
•  Each 90° elbow equals 5' (1.5 m) duct. 
•  Use no more than three 90° elbows. 
•  Flexible metal vent is not recommended.
• Do not install two elbows together.

NOTES:

•  For ducting runs up to 30' (9.1 m), install cooktop as shipped.
•  For ducting runs of 31' (9.4 m) to 60' (15.2 cm), remove the restricter 

ring on the blower inlet housing.

•  For altitudes above 4500' (1272.0 m), reduce recommended vent run 

by 20% for best performance.

3

1

4

" x 10" 

(8.3 cm x 25.4 cm) duct

Transition elbow

6" (15.2 cm) 

diameter elbow

5" (12.7 cm ) to 6" (15.2 cm) 

diameter transition 

6" (15.2 cm) 

diameter wall cap

6" (15.2 cm) diameter duct – 

51

1

2

' (15.7 m) max. 

THROUGH FLOOR BETWEEN JOISTS TO OUTSIDE

SIDE DUCTING IN TOE KICK TO OUTSIDE

DUCTING REQUIREMENTS

COOKTOP

DUCT LENGTH

DUCT SIZE

Gas

10' (3.0 m) or less*

5" (12.7 cm)  

diameter*

Between 10' (3.0 m) 

and 60' (18.3 m)

6" (15.2 cm)  

diameter

3

1

4

" x 10"  

(8.3 cm x 25.4 cm)

Electric

10' (3.0 m) or less**

5" (12.7 cm)  

diameter**

Between 10' (3.0 m) 

and 60' (18.3 m)

6" (15.2 cm)  

diameter

3

1

4

" x 10"  

(8.3 cm x 25.4 cm)

  *Gas cooktops must use 5" (12.7 cm) diameter for runs of 10' (3.0 m) or less.
** May be used to vent straight out the back of the cooktop and directly through 

the wall.

Содержание JED4430W

Страница 1: ... CONTROL JED4536W 351 2 x 183 8 x 221 8 PRODUCT DIMENSIONS MODEL JED4536W in cm A Overall width Euro Style Stainless 351 2 90 0 Floating Glass 353 8 89 8 B Overall depth Euro Style Stainless 221 8 56 2 Floating Glass 22 55 9 C Width of recessed cooktop 343 8 87 3 D Width of blower motor assembly 121 2 31 8 E Height from blower motor to countertop 183 8 46 8 F Height of recessed cooktop 37 8 10 0 G...

Страница 2: ...ning option 163 4 42 4 J Depth of upper cabinet recommended 13 33 0 K Depth from cutout to wall min 11 2 3 8 L Width of cutout 341 2 87 6 M Depth of cutout 211 8 53 7 N Depth from cutout to front of countertop 2 5 1 e Recommended electrical access location v Recommended venting location see page 3 4 for ducting information Dimension can be reduced by 6 15 2 cm when bottom of wood or metal cabinet ...

Страница 3: ... kit JDA7000WX is approved for use with JX3 downdraft cooktop models JGD3536B JGD3430B JED4536W JED3536W JED4430W and JED3430W The kit filters the air from the downdraft system and ventilates the conditioned air into the room through the toe kick of the base cabinet Do not ventilate the air from the downdraft system into the base cabinet base cabinet pedestal crawl space wall or attic PRODUCT DIME...

Страница 4: ...duct Use no more than three 90 elbows Flexible metal vent is not recommended Do not install two elbows together NOTES For ducting runs up to 30 9 1 m install cooktop as shipped For ducting runs of 31 9 4 m to 60 15 2 cm remove the restricter ring on the blower inlet housing For altitudes above 4500 1272 0 m reduce recommended vent run by 20 for best performance 31 4 x 10 8 3 cm x 25 4 cm duct Tran...