Jenn-Air JEC8536AD Скачать руководство пользователя страница 2

Component Testing Procedures

!

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.

16022396 Rev. 0

June 2003

2

Illustration

Component

Test Procedure

Results

1200 W

6

"

1800 W

6

"

oval

1800 W

7

"

2000 W

8

"

2200 W

8

"

2400 W

6/9

"

Ribbon radiant
elements

Remove one wire lead from element
and measure resistance of the
element.

Dual element

1000 + 1400 = 2400 W

Continuity, if not replace.
6

"

1200W: 44 to 49

Approximately

6

"

1800W: 50 k

Approximately

7

"

1800W: 29 to 33

Approximately

8

"

2000W: 26 to 30

Approximately

8

"

2200W: 24 to 27

Approximately

2400W: 1000 W

Inner 53 to 59

1400 W

Outer 38 to 42

Ribbon surface
thermal limiter/hot
light switch

Turn surface element on and test for
voltage. See wiring diagram and
schematic.

1a

2a 240 VAC

1b

2b 120 VAC

Disconnect leads and measure
resistance on the following:

1a

2a room temperature

continuity

1b

2b room temperature

infinite

240 VAC

Electrovac

1b

1a

2a

2b

Hot light

Heater

circuit

circuit

Therm-O-Disc (TOD)

1b

2b

2a

1a

Hot light

Heater

circuit

circuit

L2

L1

H2

P

H1

1

2

3

4

5

Infinite switch

Primary Heating Element

Term. 4

H2

Term. 1

H1

Heater

N

L1

L2

Term. 2

P

Term. 3

L1

Term. 5

L2

Remove wiring from terminals H1 and
H2. Connect Volt

-

ohms meter to

H1 and H2.

Measure the following for voltages at
LO, MED, HI:

H1 to H2

Time On

Time Off

LO

5%

95%

MED (4-5)

50%

50%

HI

100%

0%

240 VAC, if not, replace switch.

TOP

P1

2

P2

4a

4

S2

S1

EGO

Dual infinite switch

2

4

4a

S2

S1

P2

P1

(L1, 2)

(H1, 3)

(H2, 4)

(P, 5)

(L2)

ELEMENT

EGO

Remove wiring from terminals H1 and
H2. Connect Volt

-

ohms meter to

H1 and H2.

Measure the following for voltages at
LO, MED, HI:

H1 to H2

Time On

Time Off

LO

5%

95%

MED (4-5)

50%

50%

HI

100%

0%

240 VAC, if not, replace switch.

Indicator light

Measure voltage at indicator light.

If voltage is present and light does not
work replace light.
If no voltage is present at indicator light
check wiring.

https://appliancetechmanuals.com

Отзывы: