background image

2

COOKTOP SAFETY

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 

Read and follow the instructions provided with any tools listed 

here.

Tools needed

 

Tape measure

 

1/4" (6.3 mm) nut driver

 

Marker or pencil

 

Pliers

 

Flat-blade screwdriver

Parts supplied

 

Foam strip roll

 

Clamping brackets (2)

 

2½" (6.4 cm) clamping

 

Screws (2)

Parts needed

 

A UL listed or CSA approved connector for 1/2" (1.3 cm) 

diameter conduit

 

UL listed wire connectors

Check local codes. Check existing electrical supply. See the 

“Electrical Requirements” section.
It is recommended that all electrical connections be made by a 

licensed, qualified electrical installer.

Location Requirements

IMPORTANT:

 Observe all governing codes and ordinances. 

When installing cooktop, use minimum dimensions given.

 

To eliminate the risk of burns or fire by reaching over the 

heated surface units, cabinet storage space located above 

the surface units should be avoided. If cabinet storage is to 

be provided, the risk can be reduced by installing a range 

hood that projects horizontally a minimum of 5" (12.7 cm) 

beyond the bottom of the cabinets.

 

The cooktop must be a specified cooktop that is approved 

to be installed either alone or over an undercounter built-in 

oven. Check the cooktop base for an approved installation 

label. If you do not find this label, contact your dealer to 

confirm that your cooktop is approved.

 

The cooktop must be installed in a level countertop.

 

Ovens approved for this type of installation will have an 

approval label located on the top of the oven. If you do 

not find this label, contact your dealer to confirm that your 

oven is approved. Refer to oven manufacturer’s Installation 

Instructions for approval for built-in undercounter use and 

proper cutout dimensions.

 

The cooktop should be installed away from strong draft 

areas, such as windows, doors, fans or strong heating vents. 

The cooktop should be located for convenient use in the 

kitchen.

 

Use the countertop opening dimensions that are given 

with these Installation Instructions. Given dimensions are 

minimum clearances and provide 0" (0 cm) clearance.

 

Grounded electrical supply is required. See “Electrical 

Requirements” section.

IMPORTANT:

 To avoid damage to your cabinets, check with 

your builder or cabinet supplier to make sure that the materials 

used will not discolor, delaminate, or sustain other damage.

You can be killed or seriously injured if you don't immediately 
 

You

 

can be killed or seriously injured if you don't follow 

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.

Your safety and the safety of others are very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety 
messages.

This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”

These words mean:

follow instructions.

instructions.

DANGER

WARNING

05-Sep-2019 13:08:05 EDT | RELEASED

In some European factories the letter "W" of the part code mentioned herein will be automatically

replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")

Содержание JEC3430HS

Страница 1: ... 5 Install Cooktop 5 Make Electrical Connection 7 Attach Cooktop to Countertop 9 Complete Installation 9 SÉCURITÉ DE LA TABLE DE CUISSON 10 EXIGENCES D INSTALLATION 10 Outils et pièces 10 Exigences d emplacement 10 Spécifications électriques 12 INSTRUCTIONS D INSTALLATION 14 Préparation de la table de cuisson pour l installation 14 Installation de la table de cuisson 14 Raccordement électrique 16 ...

Страница 2: ...ven If you do not find this label contact your dealer to confirm that your oven is approved Refer to oven manufacturer s Installation Instructions for approval for built in undercounter use and proper cutout dimensions The cooktop should be installed away from strong draft areas such as windows doors fans or strong heating vents The cooktop should be located for convenient use in the kitchen Use t...

Страница 3: ... K G L C F B H J A 24 60 9 cm on 24 models 30 76 2 cm on 30 models 36 91 4 cm on 36 models B Combustible area above countertop shown by dashed box above C 30 76 2 cm minimum clearance between top of cooktop platform and bottom of uncovered wood or metal cabinet 24 61 cm minimum clearance if bottom of wood or metal cabinet is covered by not less than 1 4 0 6 cm flame retardant millboard covered wit...

Страница 4: ...le Family Model Number Electrical Ratings at 60 Hz 208 V 240 V JEC3430H 6 4 kW 8 5 kW JEC3536H 7 9 kW 10 5 kW JEC4424H 5 5kW 7 3 kW JEC4430H 7 2 kW 9 6 kW JEC4536H 7 2 kW 9 6 kW The cooktop should be connected directly to the junction box through flexible armored or nonmetallic sheathed copper cable The flexible armored cable extending from the fuse box or circuit breaker box should be connected d...

Страница 5: ...le place cooktop right side up into the cutout NOTE Make sure that the front edge of the cooktop is parallel to the front edge of the countertop If repositioning is needed lift entire cooktop up from cutout to avoid scratching the countertop Style 2 Cooktop over cabinets 1 Determine whether your cabinet construction provides clearance for installing clamping brackets at cooktop base ends 24 60 9 c...

Страница 6: ...re perpendicular to the edge of the cooktop base and extend beyond its edge Securely tighten screws Installing Brackets After Placing Cooktop in Cutout 1 Using 2 or more people place cooktop right side up into the cutout NOTE Make sure that the front edge of the cooktop is parallel to the front edge of the countertop If repositioning is needed lift entire cooktop up from cutout to avoid scratching...

Страница 7: ...ct power 2 Remove junction box cover if present 3 Connect the flexible cable conduit from the cooktop to the junction box using a UL listed or CSA approved connector for 1 2 1 3 cm conduit 4 Tighten screws on conduit connector if present 5 Connect the two black wires together using the UL listed wire connectors 6 Connect the two red wires together using the UL listed wire connectors 7 Connect the ...

Страница 8: ...t 3 Connect the flexible cable conduit from the cooktop to the junction box using a UL listed or CSA approved conduit connector 4 Tighten screws on conduit connector if present 5 Connect the two black wires together using the UL listed wire connectors 6 Connect the two red wires together using the UL listed wire connectors 7 Connect the green or bare ground wire from the cooktop cable to the green...

Страница 9: ...all packaging materials 4 Use a mild solution of liquid household cleaner and warm water to clean cooktop before use Dry thoroughly with a soft cloth For more information see the Cooktop Care section of the Use and Care Guide 5 Read the Cooktop Use section in the cooktop Use and Care Guide 6 Reconnect power 7 For further information about the product read the User Instructions NOTE If the cooktop ...

Страница 10: ...tiquette contactez votre marchand pour confirmer que le four est bien approuvé Consulter les Instructions d installation du fabricant du four pour déterminer si l utilisation en encastrement est approuvée et pour obtenir les dimensions correctes de l ouverture La table de cuisson doit être installée à l écart des zones de forts courants d air telles que fenêtres portes et évents ou ventilateurs de...

Страница 11: ... travail I Boîtier de connexion ou prise 9 23 cm maximum à partir de la droite du placard J 29 2 74 9 cm recommandé pour l ouverture découpée sur les modèles de 30 76 2 cm Convient à une ouverture découpée de 29 16 299 16 73 8 90 3 cm sur les modèles de 30 76 2 cm 35 2 90 2 cm recommandé pour l ouverture découpée sur les modèles de 36 91 4 cm Convient à une ouverture découpée de 349 16 359 16 87 8...

Страница 12: ...canadien de l électricité Partie 1 et C22 2 N O M91 dernière édition et à tous les codes et règlements locaux Pour obtenir un exemplaire des normes des codes ci dessus contacter National Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 D C A B E F E Table de cuisson Bande de mousse A Profondeur de la zone ...

Страница 13: ...ible à conducteur de cuivre avec blindage ou gaine non métallique Le câble blindé flexible sortant du boîtier de distribution fusible ou disjoncteur doit être raccordé directement au boîtier de connexion Placer le boîtier de connexion pour laisser le plus de jeu possible entre celui ci et la table de cuisson pour pouvoir déplacer la table de cuisson en cas de besoin de réparation à l avenir Ne pas...

Страница 14: ...sson dans l ouverture en orientant la bonne surface vers le haut REMARQUE S assurer que le bord avant de la table de cuisson est parallèle au bord avant du plan de travail S il est nécessaire de repositionner la table de cuisson la soulever entièrement de l ouverture pour éviter de rayer le plan de travail Style 2 Table de cuisson sur placards 1 Déterminer si l installation des placards permet le ...

Страница 15: ...r qu elles soient perpendiculaires au bord de la base de la table de cuisson et qu elles dépassent de son bord Bien serrer les vis Installation des brides après avoir positionné la table de cuisson dans l ouverture 1 À l aide d au moins 2 personnes placer la table de cuisson dans l ouverture en orientant la bonne surface vers le haut REMARQUE S assurer que le bord avant de la table de cuisson est ...

Страница 16: ...int de distribution 1 Déconnecter la source de courant électrique 2 Enlever le couvercle du boîtier de connexion le cas échéant 3 Avec le connecteur de conduit homologation UL ou CSA pour conduit de 1 2 1 3 cm connecter le conduit de câble flexible de la table de cuisson au boîtier de connexion 4 Serrer les vis du connecteur de conduit le cas échéant 5 Connecter ensemble les deux conducteurs noirs...

Страница 17: ...mologation UL ou CSA connecter le conduit de câble flexible de la table de cuisson au boîtier de connexion 4 Serrer les vis du connecteur de conduit le cas échéant 5 Connecter ensemble les deux conducteurs noirs avec un connecteur de fils homologation UL 6 Connecter ensemble les deux conducteurs rouges avec les connecteurs de fils homologation UL 7 Connecter le conducteur vert ou nu de liaison à l...

Страница 18: ...x d emballage 4 Avant d utiliser la table de cuisson utiliser une solution douce de nettoyant domestique et d eau tiède pour la nettoyer Sécher parfaitement avec un linge doux Pour plus de renseignements voir la section Entretien de la table de cuisson du Guide d utilisation et d entretien 5 Lire Utilisation de la table de cuisson dans le Guide d utilisation et d entretien de la table de cuisson 6...

Страница 19: ... Remarques 05 Sep 2019 13 08 05 EDT RELEASED In some European factories the letter W of the part code mentioned herein will be automatically replaced by the number 4000 e g W12345678 becomes 400012345678 ...

Страница 20: ...us droits réservés Utilisé sous licence au Canada 09 19 W11236401C 05 Sep 2019 13 08 05 EDT RELEASED In some European factories the letter W of the part code mentioned herein will be automatically replaced by the number 4000 e g W12345678 becomes 400012345678 ...

Отзывы: