BBDUDBHQBE±3DJHRI
5.7.3 Measuring
winding
resistance of the BLDC motor
Measure winding resistance at 25° on the winding contacts of the
heating pump.
Technical specifications:
Resistance:
approx. 41.5
Ω
± 4
Ω
or
approx. 53.5
Ω
± 4.5
Ω
according to manufacturer
Technical specifications:
Resistance:
12
Ω
bis 14
Ω
Resistance measurement
►
The resistance values are approx. values.
There must be symmetry for all measurements
(same resistance values).