GAS REQUIREMENTS
L.P. Gas Installation
Jenn-Air Gas Grills that are set to operate with L.P. gas come with a high capacity hose and regulator
assembly. This assembly is designed to connect directly to a standard 20 lb. L.P. cylinder.
Attach the gas hose assembly to the brass 3/8 flared fitting on the under side of the grill. Tighten securely and
attach other end to the propane tank. (sold separately) (See Fig. 12)
L.P. Tank Information
Never use a dented or rusted L.P. tank or cylinder with a damaged valve.
The L.P. cylinder must be provided with a shut-off valve terminating in an L.P. gas supply cylinder outlet
specified, as applicable, for connection No. 510 in the standard for compressed gas cylinder valve outlet and
inlet connection ANSI/CGA-V-1. Cylinders must not be stored in a building, garage, or any other enclosed
area. (The L.P. cylinder must have an overfill protection device on it.)
The L.P. Gas supply cylinder must be constructed and marked in accordance with the specifications for L.P.
gas cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada,
CAN/CAS-B339, “Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods.”
9
Fig. 12