5. Electrode Efficiency Mode. 
In MEASURE mode, press       
the “Enter” key for about 5 
seconds to display the 
electrode’s efficiencies.

 

 
 
 
 
B.  Keypad Operations

 

 

 

Key

 

Operation
Mode

 

 

Duration

 

Function

 

 

On/Off

 

All 

0 seconds

Turns meter on/off.

 

 

Measure

 

0 seconds

Enters Calibration Mode.

 

Measure 5 

seconds

Enters Buffer Select 

Mode.

 

 
 

Cal

 

Calibration

0 seconds

Recalibrates the buffer.

 

Measure

 

0 seconds

Holds measured values. 

Press again to resume 
measuring.

 

 

 

Hold

 

Calibration

0 second

Exits pH calibration. 

Measure

 

5 seconds

Displays the electrode’s 

efficiencies. 

 
 

Enter

 

Calibration

0 seconds

Saves the calibration 
data. 

 

 

 

USING VISIONPLUS pH 619   

 

 

A.  Power ON/OFF 

 

Press the “On/Off ” key to turn the unit on. If the unit is running 

then you can press the ”On/Off “ key to turn the unit off. The 

will automatically turn off after 30 minutes of no key activity. 

 

B.  Select Buffer

 

1. Make sure unit is in MEASURE mode. 

2. Press the “CAL” key for 5 Seconds. The unit will display 

7.00 to indicate you successfully changed from 

“6.86/4.00/9.18” set to “7.00/4.01/10.01” set.   

 
 

Содержание pH619

Страница 1: ...Operation Manual MODEL pH 619 Microcomputer Based pH Temperature Pocket Meter pH619...

Страница 2: ...nd Meter 2 VISIONPLUS pH 619 OVERVIEW 3 A Meter Description 3 B VisionPlus Graphical Display 3 OPERATION MODES AND KEYPAD OPERATIONS 4 A Operation Modes 4 B Keypad Operations 5 USING VISIONPLUS pH 619...

Страница 3: ...instrument can operate within specifications for approximately 2 3 hours after low battery appears 1 Shown in the right figure 2 Take off the battery cover 3 Remove all of the old batteries and inser...

Страница 4: ...Keypad 4 Electrode collar 5 Electrode ATC assembly Electrode cap is not shown B VisionPlus Graphical Display 1 MEASURE mode indicator 2 pH reading 3 CALIBRATION buffer s 4 BATTERY display 5 TEMPERATU...

Страница 5: ...ll pH and temperature measurements 2 Calibration Mode Calibration Mode is used to perform 1 2 or 3 point calibration 3 Hold Mode Hold Mode is used to display held measured values for increased ease of...

Страница 6: ...in to resume measuring Hold Calibration 0 second Exits pH calibration Measure 5 seconds Displays the electrode s efficiencies Enter Calibration 0 seconds Saves the calibration data USING VISIONPLUS pH...

Страница 7: ...er key the SAVE icon will be on Wait a second the first point has been calibrated and the unit is ready to be sloped at the second buffer Note At this moment press the Hold key the unit will exit the...

Страница 8: ...bration mode Three points calibration is complete Note For accurate measurements it is recommended that pH calibration is preformed once a week and after replacing the electrode D Measure Dip the mete...

Страница 9: ...00 0 C pH pH 14 00pH Over Range or Recalibrate OVER 0 0 60 0 C pH CAL a pH OFFSET b pH SLOPE a Offset 7 00pH mV 100mV Offset 6 86pH mV 108 3mV b New slope ideal slope by 30 Use a new buffer solution R...

Страница 10: ...pH Electrode Slope recognition 30 at pH 4 00 4 01 9 18 and 10 01 Input impedance 1012 Temperature Temperature sensor Thermistor 10 k at 25 C Temperature unit Factory pre set General Power LR44 x 4 Bat...

Страница 11: ...ection items must be carefully packed to prevent damage in shipment and insured against possible damage or loss Jenco will not be responsible for damage resulting from careless or insufficient packing...

Страница 12: ...619 TC CHEN 2008 8 10 K619 01 2009 6 26 01 2009 6 26 618N 090626...

Отзывы: