18
AF-1 and AF-2 fans user manual
To set timer operation using the remote control:
1. Set the desired amount of airflow using the SPEED control
2. Set intervals between operating periods by setting the DELAY control
to between 1 and 9.
3. Set duration of operating periods by setting the RUN control to
between 1 and 9.
4. Set the STANDBY button to ON
5. Set the TIMER ON button to ON.
The CYCLE LED lights when the timer function is active.
To extend timer settings, press the X8 button. This will multiply both RUN
and DELAY times by 8.
D M X c o n t r o l
Fan speed on the AF-1 and AF-2 fans can be controlled using a DMX
controller.
DMX controller op eration
When a fan is powered on, the Data LED next to the DIP-switch will light
when a valid DMX signal is received.
Increase the value on the machine’s DMX control channel to increase fan
speed as shown below:
D M X c o n t r o l c h a n n e l l e v e l s
Level
Percentage
Effect
0-27
28-255
0-10%
11-100%
Fan speed zero.
1 - 100% fan speed.
Содержание AF-1