11
JREMO 6K
Industrial radio remote controller
CHAPTER 3. INSTALLATION & FUNCTION SETTING
the software.
C. Direct Copying from Rx
1. Connect Tx and Rx by a connector cable (an optional provision).
2. Place the COPY-RUN s/w nob to COPY position, and Tx Led will blink
with green light.
3. Paring (Copying) from Rx to Tx done.
4. Unplug the connector and place the s/w to RUN position.
D. Consult
JEICO
distributor and/or agent for further support.
3-3 HOW TO INSTALL
JREMO
® SERIES RX
3-3-1. PREPARATIONS
A. Prepare tools.
B. Select a proper place for installation.
1. Choose a safe area, a visible area of receiver or antenna.
2. Avoid a spark area (ex. motors, relays, magnet switches, electric cables
are likely generating sparks and interferes)
3. Avoid high voltage and current area.
4. Receiver is to be distanced at least 3cm from obstacles.
C. Match receiver power
1. Check input power source and make sure to connect to the right position.
2. In case DC power, make sure receiver is also for DC.
3. AC Power
Use AC Receiver.
Standard AC power source is 110 ~ 440V Free Volts.
24V, 48V etc. are optional.
4. DC Power
Use DC Receiver.
Standard DC power source is DC12 ~ 40V Free Volts.
For 48VDC, 60VDC consult
JEICO