background image

7.7

 A marine (boat) battery must be removed and charged on shore. To charge it on board requires equipment 

specially designed for marine use. 

8. GROUNDING AND AC POWER CORD CONNECTIONS
8.1

 This battery charger is for use on a nominal 120 volt circuit. The plug must be plugged into an outlet that is properly

installed and grounded in accordance with all local codes and ordinances. The plug pins must fit the receptacle (outlet).
Do not use with an ungrounded system.

8.2

 

DANGER:

 Never alter the AC cord or plug provided 

– if it does not fit the outlet, have a proper grounded outlet

installed by a qualified electrician. An improper connection can result in a risk of an electric shock or electrocution.

8.3 USING AN EXTENSION CORD

The use of an extension cord is not recommended. If you must use an extension cord, follow these guidelines:

• Pins on plug of extension cord must be the same number, size, and shape as those of plug on charger.
• Ensure that the extension cord is properly wired and in good electrical condition.
• Wire size must be large enough for the AC ampere rating of charger, as specified:

Length of cord (feet)  25  50  100  150 
AWG* size of cord 

18  18  16 

14 

* AWG 

– American Wire Gauge

9. ASSEMBLY INSTRUCTIONS
9.1

 Remove all cord wraps and uncoil the cables prior to using the battery charger.

10. CONTROL PANEL

START/STOP BUTTON 

Press to immediately begin charging your properly connected battery

. If the button is not pressed, charging 

should begin in ten minutes. 
CHARGING STATUS LED INDICATORS 
CHARGING (yellow/orange) LED lit: 

The charger is charging the battery. 

CHARGED (green) LED lit: 

The battery is fully charged and the charger is in maintain mode. 

CLAMPS REVERSED (red) LED flashing: 

The connections are reversed. 

BAD BATTERY (red) LED lit: 

The charger has detected a problem with the battery. See Troubleshooting for 

more information. 

NOTE: 

See Operating Instructions for a complete description of the charger modes. 

DIGITAL DISPLAY 

The display will show the battery voltage when the charger is not charging a battery. When it goes into charging mode, 
the display will automatically change to ON (to show charging has started) and then show the percent-of-charge of the 
battery being charged and either 6 or 12 (the voltage of the battery, determined by the charger). If you manually stop 
the charging process (by pressing the START/STOP button) before the battery is fully charged, the display will show 
OFF. 

NOTE

: During charging, the display will go into sleep mode and will not show the percentage of charge or voltage of the 

battery. To turn the display back on, press any button. 

Voltage 

 The Digital Display shows the voltage at the charger battery clamps in DC volts, or the voltage of the battery, 

depending on what mode the charger is in. 

 The Digital Display shows an estimated charge percent of the battery connected to the charger battery clamps. 

CHARGE RATE 

The charger will automatically adjust the charging current, based on battery size, in order to charge the battery 
completely, efficiently and safely. 

RATE SELECTION BUTTON 

Use this button to set the maximum charge rate. Press the button until the desired charge rate is selected. 

3A 

 For charging small batteries, such as those commonly used in garden tractors, snowmobiles and motorcycles. 

Also used to maintain fully charged large batteries. 

15A 

 For charging automotive, marine and light truck batteries. Not intended for industrial applications.

1-800-345-4545   jegs.com

Содержание 81992

Страница 1: ...1 11 WARNING RISK OF EXPLOSIVE GASES a WORKING IN VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT YOU FOLLOW THE INSTRUCTIONS EACH TIME YOU USE THE CHARGER b To reduce risk of battery explosion follow these instructions and those published by battery manufacturer and manufacturer of any ...

Страница 2: ... 6 2 Stay clear of fan blades belts pulleys and other parts that can cause injury to persons 6 3 Check polarity of battery posts POSITIVE POS P battery post usually has larger diameter than NEGATIVE NEG N post 6 4 Determine which post of battery is grounded connected to the chassis If negative post is grounded to chassis as in most vehicles see 6 5 If positive post is grounded to the chassis see 6...

Страница 3: ...arged and the charger is in maintain mode CLAMPS REVERSED red LED flashing The connections are reversed BAD BATTERY red LED lit The charger has detected a problem with the battery See Troubleshooting for more information NOTE See Operating Instructions for a complete description of the charger modes DIGITAL DISPLAY The display will show the battery voltage when the charger is not charging a batter...

Страница 4: ... result in damage to the charger and your vehicle NOTE This charger is equipped with an auto start feature Current will not be supplied to the battery clamps until a battery is properly connected The clamps will not spark if touched together CHARGING A BATTERY IN THE VEHICLE 1 Turn off all the vehicle s accessories 2 Keep the hood open 3 Clean the battery terminals 4 Place the charger on a dry non...

Страница 5: ...the maintain mode of operation MAINTAIN MODE FLOAT MODE MONITORING When the Charged green LED is lit the charger has started maintain mode In this mode the charger keeps the battery fully charged by delivering a small current when necessary If the charger has to provide its maximum maintain current for a continuous 12 hour period it will go into abort mode see Aborted Charge section This is usuall...

Страница 6: ...l automatically switch from tester to charger if a battery is connected In that case the charger will be set to charge at the 15A rate and AGM battery type 12 MAINTENANCE AND CARE A minimal amount of care can keep your battery charger working properly for years Clean the clamps each time you are finished charging Wipe off any battery fluid that may have come in contact with the clamps to prevent c...

Страница 7: ...harging The Bad Battery LED is lit The battery voltage is still below 10V for a 12V battery or 5V for a 6V battery after 2 hours of charging or In maintain mode the output current is more than 1 5A for 12 hours Desulfation was unsuccessful Lack of progress is detected and battery voltage is below 14 2V for a 12V battery or 7 1V for a 6V battery The battery s initial voltage is below 12 2V for a 12...

Страница 8: ... approved for use with this product This Limited Warranty is void if the product is misused subjected to careless handling repaired or modified by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer Manufacturer makes no other warranties including but not limited to express implied or statutory warranties including without limitation any implied warranty of me...

Отзывы: