TROUBLESHOOTING
Symptom
Possible Cause
Action
Engine won't start
Not enough fuel oil
Add fuel - see section "4. Checking Generator
Prior to Use"
Fuel nozzle cannot inject fuel or there
is not enough fuel
Repair the fuel injector
The speed control lever is not in the
"Run" position
Move the lever to the "Run" position
Lubricant oil level is too low
Check that the oil level is topped up and sits
between the upper and lower level markers
Not enough speed or force used on
the
starter/recoil handle
See section "5. Starting the Generator"
The fuel nozzle is blocked or dirty
Clean tthe fuel nozzle
Generator fault
Circuit breaker is not closed
Turn the circuit breaker to the "On" position
Poor or faulty socket connection
Adjust the socket feet
The rated generator speed cannot be
obtained
Adjust to rated speed
Carbon brush is faulty or worn
Replace the carbon brush
AVR is depreciated
Replace the AVR