IMPORTANT: 

The safety valves supplied with this equipment are designed and constructed for use exclusively with compressed air, free from 

impurity. The materials used in construction are suitable for operating the valve at the rated pressure and temperatures. The viton or NBR gasket 
conserves the resistance characteristics, even in prolonged use. The valve caulking is designed to impede calibration, modification or tampering. 
Any modification or recalibaration of the safety valve will nullify warranty and potentially make the equipment unsafe. 

Valve installation must be performed exclusively by Jefferson approved engineers. Checking the integrity of the valve before installation is 
obligatory. Also, check that the valve pressure is no greater than the operating pressure of the tank or of the system that it is installed with. 

• 

Check that the discharge flow rate of the valve is greater than the quantity of the air to discharge. 

• 

The safety valve must be positioned directly on the tank in a vertical position, in a dry, accessible place protected against the weather and far 
away from liquids or condensation. 

• 

It must be positioned to allow sufficient space all around for correct air discharge, without causing damage to persons or the surrounding 
area.

• 

The valve rod must be free in its movement when discharging. 

• 

The connection between the valve and the part to be protected must be free from all kinds of choking and be as short as possible so as not 
to reduce the discharge flow rate of the valve itself. 

• 

The connection passage area must be greater than the valve orifice area. 

• 

During installation screw on the valve with a torque spanner using the hexagonal part of the body. 

• 

Apply a maximum torque of 

30Nm

, paying attention not to cause any deformation; using pincers, pliers, hammers or tools other than a 

hexagonal spanner is forbidden and will void warranty. 

• 

Check that the inlet hole and the shutter are not blocked by glue, Teflon or similar materials that could bind the shutter or other functional 
components. 

• 

If the valve is replaced the compressed air contained in the system must be discharged first.  
 

WARNING:

 

Jefferson Tools cannot take any responsibility for damage caused to persons and/or things due to failure to observe these instructions.

ON/OFF SWITCH

Prior to connecting the compressor to the power supply, ensure the pressure switch is on 
the 

OFF 

position. On initial start-up open the reservoir condensate drain bung (

A

) (

Fig.10

 

, adjust the pressure regulator (

B

) (

Fig.11)

 to the maximum pressure. Unscrew the bung 

anti-clockwise to open valve.

Pull the pressure switch (

C

) up to start the compressor. 

NOTE: 

The switch may be a "Lever" or "Button" type as shown in (

Fig.11

), depending on 

your compressor model. 

Allow the machine to run for 10 minutes with the air escaping from the reservoir tank 
before closing the drain bung (

A

). 

Ensure the tank pressure reaches 10 bar as indicated on the gauge (

D

) before the 

pressure switch shuts off the motor.

NOTE:

 

When the drain bung is closed the tone from the motor will change. The 

compressor motor will automatically restart when the tank pressure drops to approximately 
3-4 bar less than the maximum pressure.

WARNING: 

Never stop the compressor using the mains connection. Always switch off 

the compressor by pressing the pressure switch button down. The compressed air will be 
vented from the head and allowing an easy re-start.

NOTE: 

During correct operation a whistle of compressed air escaping/releasing will be 

heard when the motor strops and a protracted whistle (approx. 20-30 seconds) whenever 
the compressor is started with no pressure in the tank.

  SAFETY VALVE

 

  OPERATION GUIDE

 

   

Fig.10

 

A

 

 "

Lever Switch" Type

D

C

B

 

 "

Button Switch" Type

C

B

D

   

Fig.11

 

   

Fig.11

 

All manuals and user guides at all-guides.com

Содержание JEFC200L10B-230

Страница 1: ...User Manual v 2 3 JEFC200L10B 230 AIR COMPRESSOR 200L 230V 50Hz 10Bar 3HP BELT DRIVE All manuals and user guides at all guides com ...

Страница 2: ...USER MANUAL JEFC200L10B 230 200L AIR COMPRESSOR 230V 50Hz 3HP 10Bar BELT DRIVE www jeffersontools com 2 All manuals and user guides at all guides com ...

Страница 3: ...ety Guidelines 8 Warning Labels 10 Safety Valve 11 Operation Guide 11 Maintenance 13 Troubleshooting 14 Environmental Protection 15 WEEE Waste Electrical and Electronic Equipment Statement 15 Parts Diagram Main Assembly 16 Parts List Main Assembly 17 Parts Diagram Pump 18 Parts List Pump 19 EC Declaration of Conformity 20 Limited Warranty Statement 21 CONTENTS All manuals and user guides at all gu...

Страница 4: ...to assist you in the safe operation and maintenance of the compressor Some illustrations in this Instruction Manual may show details or attachments that differ from those on your own compressor Contact your nearest Jefferson Dealer if you are unsure about any information included in this manual or require any additional information about the safe use operation maintenance or repair of this equipme...

Страница 5: ...xpel the bung along with oil from the head possibly leading to damage PLEASE NOTE THE FOLLOWING PHOTOGRAPHS INSTRUCTIONS ARE FOR REFERENCE ONLY AND MAY DIFFER FOR YOUR COMPRESSOR MODEL PLEASE CONTACT JEFFERSON TOOLS IF YOU NEED ANY ADVICE ON THE ASSEMBLY PROCEDURE Position the compressor on a flat surface or with a maximum permissible inclination of 10 Fig 3 in a well aired place protected against...

Страница 6: ...lator 3 Air Outlet Quick Release 12 Pressure Gauge 4 Pressure Switch 13 Check Valve 5 Transportation Handle 14 Tank Rating Plate 6 Belt Guard 15 Ball Valve 7 Motor Assembly 16 Back Wheels 8 Air Filter 17 Tank Drain Valve 9 Pump Assembly 18 Front Castors 1 EQUIPMENT IDENTIFICATION 2 3 4 5 6 7 9 10 8 11 12 13 15 14 16 17 18 All manuals and user guides at all guides com ...

Страница 7: ...pressor must be used on a flat level surface The maximum safe operating angle in any direction is 15 degrees see Fig 8 Do not operate the compressor on inclines in excess of 10 degrees Serious damage to pump components may result from insufficient lubrication Never use the air compressor on a rooftop or elevated position that could allow the unit to fall or be tipped over Use additional air hose f...

Страница 8: ...nsure that it is safe for use Portable equipment means any electrical item that can be moved and this is often referred to as Portable Appliance Testing PAT PAT testing should be carried out regularly on this equipment by trained authorised personnel as required by the legislation The Health and Safety at Work Act 1974 states that it is the responsibility of the owner of electrical appliances to e...

Страница 9: ...pt clean so that air can freely flow at all times Check for dust build up frequently and clean as required If the equipment appears to be operating unusually making strange noises or otherwise appears defective stop using it immediately and arrange for repairs by a authorized service centre Solvents such as petrol thinner benzine carbon tetrachloride and alcohol may damage and crack plastic parts ...

Страница 10: ... with the air compressor Operate the air compressor in well ventilated areas free from obstructions Equip areas with fire extinguishers suitable for electrical fires Do not leave nylon material shirts or jumpers on the compressor Store paint thinners and other flammable liquids in approved containers in a secure location away from the work area Minimum clearance 0 5m Maximum ambient operating temp...

Страница 11: ...ng attention not to cause any deformation using pincers pliers hammers or tools other than a hexagonal spanner is forbidden and will void warranty Check that the inlet hole and the shutter are not blocked by glue Teflon or similar materials that could bind the shutter or other functional components If the valve is replaced the compressed air contained in the system must be discharged first WARNING...

Страница 12: ...e life of the regulator and avoid damage AIR LINE CONNECTION The compressor comes equipped with a quick in line female connector To insert a male connector pull the collar backwards and insert the male connection When fully inserted release the collar If a different style of connection is required the connector can be replaced NOTE When fitting the replacement ensure the threads are sealed with PT...

Страница 13: ...y you can use some PTFE tape on the thread to help create a tighter seal before tightening Fill the oil reservoir with a compatible compressor oil e g Jefferson HT68 Compressor Oil Checking Cleaning the Air Filter Ensure the compressor is turned off and disconnected from the power source Allow the compressor pump and other parts to cool off if changing filter after use Unscrew the filter top from ...

Страница 14: ...re is a leak from the base of the pressure switch when the compressor is stopped The non return valve from the tank is leaking Disassemble and clean if necessary replace valve insert Contact your authorised service agent The compressor is noisy with metallic clangs knocks Bearing or piston problem Low oil level Stop the compressor and contact a specialized service technician The compressor sounds ...

Страница 15: ...opriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with you national legislation For business users in the European Union If you wish to discard electrical and electronic equipment please contact your dealer or supplier for further information Infor...

Страница 16: ...USER MANUAL JEFC200L10B 230 200L AIR COMPRESSOR 230V 50Hz 3HP 10Bar BELT DRIVE www jeffersontools com 16 PARTS DIAGRAM MAIN ASSEMBLY All manuals and user guides at all guides com ...

Страница 17: ...1 PL Washer 11 1 Ball Valve 38 1 Hex Nut 12 1 Pressure Regulator 39 1 Pump 13 1 Pressure Gauge 40 1 Bracket 14 3 Quick Coupler 41 1 Hex Bolt 15 1 Bonnet 42 1 Hex Bolt 16 1 Spring Check valve 43 1 Motor Pulley 17 1 Valve Element 44 1 Key 18 1 O Ring 45 1 Hex Nut 19 1 Check Valve 46 1 PL Washer 20 1 Check Valve 47 4 Bolt 21 1 Elbow Fitting 48 1 Motor 22 1 Tuve Nut 49 1 Handle 23 1 Copper Tube 50 2 H...

Страница 18: ...USER MANUAL JEFC200L10B 230 200L AIR COMPRESSOR 230V 50Hz 3HP 10Bar BELT DRIVE www jeffersontools com 18 PARTS DIAGRAM PUMP All manuals and user guides at all guides com ...

Страница 19: ...port 32 2 Hex Bolt 9 2 Gasket 33 2 Sp Washer 10 2 Bearing 34 1 Radiator 11 1 Crankshaft 35 1 Gasket Radiator 12 2 Connecting Rod 36 6 Hex Socket Bolt 13 4 Circlip 37 1 Air Filter Assembly 14 2 Piston Pin 37 1 1 Case 15 2 Piston 37 2 1 Element 16 2 Oil Ring 37 3 1 Case 17 2 Oil Ring 38 1 Cylinder Head 18 2 Compression Ring 39 1 Cylinder Head Gasket 19 2 Piston Ring Kit 40 1 Valve Plate 20 1 Breathe...

Страница 20: ...s amended Simple Pressure Vessels Directive Technicka Inspekcia A s Trnavska Cesta 56 821 01 Bratislava Country Slovakia 1354 Equipment Category Air Compressor Item 8 Product Name Model 200L Air Compressor JEFC200L10B 230 200L Air Compressor 230V 3HP 10Bar Belt Drive Measured Sound Power Level Guaranteed Sound Power Level 96dB 96dB The conformity assessment procedure followed was in accordance wit...

Страница 21: ...to provide proof of purchase should a warranty claim be necessary Warranty Repair Should Jefferson confirm the existence of any defect covered by this warranty the defect will be corrected by repair or replacement at an authorized Jefferson dealer or repair centre Packaging Freight Costs The customer is responsible for the packaging of the equipment and making it ready for collection Jefferson wil...

Страница 22: ... and any repairs needed are covered by the warranty policy In order to qualify for warranty cover all equipment presented must have been used serviced and maintained as instructed in the user manual Where repair is not covered by the warranty a quotation for repair labour costs and return delivery will be sent to the customer normally within 7 working days NOTE If the repair quotation is not accep...

Страница 23: ...USER MANUAL JEFC200L10B 230 200L AIR COMPRESSOR 230V 50Hz 3HP 10Bar BELT DRIVE www jeffersontools com 23 All manuals and user guides at all guides com ...

Страница 24: ...ingdom CH4 9QR Tel 44 0 1244 646 048 Email sales jeffersontools com IMPORTANT SAFETY FIRST Before attempting to use this product please read all the safety precautions and operating instructions outlined in this manual to reduce the risk of fire electric shock or personal injury www jeffersontools com www jeffersontools com All manuals and user guides at all guides com ...

Отзывы: