![Jeep WRANGLER RUBICON 392 2021 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/jeep/wrangler-rubicon-392-2021/wrangler-rubicon-392-2021_features-manual_4169160038.webp)
36
SERVICING AND MAINTENANCE
(Continued)
Customer can select to switch the Cargo Power Outlet from F43 battery fed power to this position F45 which is fed when the ignition in ON.
F105
–
10 Amp Red
Integrated Center Stack (ICS)/Heat Ventilation Air
Conditioning (HVAC)
F106
50 Amp Red
–
Electronic Speed Control (ESC)-PUMP MTR
F107
–
20 Amp Yellow
TRAILER TOW STOP/TURN LT — If Equipped
F108
–
15 Amp Blue
HD ACCY #4 — If Equipped
F109
–
20 Amp Yellow
TRAILER TOW STOP/TURN RT — If Equipped
F110
30 Amp Pink
–
POWER INVERTER
F111
20 Amp Blue
–
TRAILER TOW BACKUP — If Equipped
Cavity
Cartridge Fuse
Micro Fuse
Description
CAUTION!
When installing the power distribution
center cover, it is important to ensure the
cover is properly positioned and fully
latched. Failure to do so may allow water to
get into the power distribution center and
possibly result in an electrical system
failure.
When replacing a blown fuse, it is important
to use only a fuse having the correct
amperage rating. The use of a fuse with a
rating other than indicated may result in a
dangerous electrical system overload. If a
properly rated fuse continues to blow, it
indicates a problem in the circuit that must
be corrected.
CAUTION!
(Continued)
20_JL_OM_EN_US_t.book Page 36