CONTENTS
ENT-2L
System
ENT-3L
System
ENT-4L
System
Item
Item
No.
(2.1mm diameter)
(3.2mm diameter)
(4.2mm diameter)
49-5020 ..............Scope (ENT-2L) ...............................1 .........................................0 ........................................ 0
49-5030 ..............Scope (ENT-3L) ...............................0 .........................................1 ........................................ 0
49-5040 ..............Scope (ENT-4L) ...............................0 .........................................0 ........................................ 1
49-4990 ..............Case .................................................1 .........................................1 ........................................ 1
49-5085 ..............EOG/EtO Adaptor.............................1 .........................................1 ........................................ 1
49-51xx ...............Light Source Adaptor........................1 .........................................1 ........................................ 1
(See page 9)
Any shipping damage should be documented and
reported immediately to the carrier or JEDMED.
NOTE
DESCRIPTION & INDICATIONS FOR USE
Carefully unpack all components. Verify contents and inspect for shipping damage.
Refer to next page for illustrations.
MACHIDA laryngo-nasopharyngoscope is also
referred to as “device”, “instrument” and/or “scope”
throughout this manual.
NOTE
MACHIDA’s laryngo-nasopharyngoscope
is a flexible fiberoptic endoscope designed
for examining the larynx, nasal cavity and
nasopharynx. These areas encompass
the upper respiratory tract from the nasal
passages to the vocal chords. MACHIDA
scopes are intended to be used by ENT
physicians in an office setting for routine
ENT procedures.
MACHIDA scopes are available in three
sizes: the 2.1mm pediatric insertion tube
diameter (ENT-2L), the 3.2mm slim-line
insertion tube diameter (ENT-3L) and the
4.2mm standard insertion tube diameter
(ENT-4L).
An industry-standard endoscope eyepiece
allows the user to look through the scope,
directly, or to indirectly observe the field by
attaching an optional endoscope coupler and
video camera.
A MACHIDA scope is a quality-designed
and manufactured medical device. Given
reasonable care, this product will provide
many years of trouble-free service.
Ethylene Oxide Gas Sterilization is also referred to
as “EtO”, “EO” and/or “EOG” throughout this manual.