background image

3

R

EAR PANEL CONTROLS 

(후면기능)

USE ONLY WITH A 250V FUSE

8

7

6

4

3

2

1

5

9

SPEAKER

SIGNAL

INPUT

INPUT

1

2

3

4

GROUP-A

1

2

3

4

GROUP-B

GROUP-B

SPARE AMP 

GROUP-A

SPARE AMP 

AMPLIFIER

OUTPUT

DC POWER

24V MAX 0.6A  

SERIAL NO.:

SPEAKER

SIGNAL

INPUT

INPUT

AMPLIFIER

OUTPUT

WARNING

:

 TO REDUCE THE RISK OF  FIRE

OR ELECTRIC SHOCK DO NOT EXPOSE THIS

EQUIPMENT TO RAIN OR MOISTURE.

CA

UT

IO

N:

 

TO

 R

ED

UC

TH

RI

SK

 O

F  

 

 

FIR

E R

EP

LA

CE

 O

NL

 W

ITH

 SA

ME

 TY

PE

 FU

SE

.

G

G

G

SPARE AMPLIFIER 

EXTENSION FAULT SIGNAL OUT

G

CA

UT

IO

N

RIS

K O

F E

LE

CT

RIC

 SH

OC

K

DO

 NO

T O

PE

N

230V     50Hz

MAX 15W

FUSE RATING T0.5AL 250V

M

O

D

EL

 N

O

: J

FA

-2

42

U

POWER CHECK

  (NON PULSE)

FAULT CHECK

 (NON PULSE)

1. SIGNAL INPUT TERMINAL

믹서 또는 프리앰프로 부터의 신호입력을 연결하기 위한 단자 입니다.

2. INPUT TERMINAL

앰프의 신호입력과연결하기 위한 단자입니다.
신호 극성에 주의하여 결선하십시오.

4. SPEAKER TERMINAL

스피커와 연결하기 위한 단자입니다. 릴레이 그룹의 AMP단자와 연결하십시오.

5. INPUT TERMINAL / FAULT SIGNAL OUT

예비 앰프의 신호입력과 연결하기 위한 단자입니다.

3. OUTPUT TERMINAL

앰프의 출력 단자와 연결하기 위한 단자이며 OUTPUT TRANSFORMER가
있는 앰프와 연결하여야 합니다. 그렇지 않은 경우에는 GROUND FAULT

LED가 켜지게 됩니다. 신호 극성에 주의하여 결선하십시오.

6. OUTPUT TERMINAL

예비앰프의 출력단자와 연결하기 위한 단자입니다. (시스템 연결방법참조)

7. DC POWER

직류 전원을 공급하기 위한 단자입니다.

FAULT SIGNAL OUT : 주 앰프의 고장신호(FAULT SIGNAL)가 출
력되는 단자입니다. 만약 예비앰프 1대에 주앰프 8대(1:8) 또는 그
이상 확장 운용시 예비 앰프 채널의 SIGNAL OUT 단자들이 연결되
어있어야 어느 주 앰프가 고장나도 예비앰프로 전환 됩니다.
(시스템 연결 방법 참조)

중요사항 : 연결시 극성이 바뀌지 않도록 주의 하십시오.
FUSE : T1AH(55T)

8. AC POWER SOCKET

교류전원 공급용 소켓입니다.

중요사항 : 사용 전압을 확인 후 전원 코드를 끼워주십시오.
그리고 휴즈가 용단시 규격품으로 교체 하십시오.
FUSE :120VAC→T1AL(S51), 220V 240VAC→T500mA(50T)

9. 주요기능 상태출력 단자

본장비의 주요기능을 검출하여 본사의 JCU-160의 입력단자에
연결하는 출력단자입니다.
JCU-160입력단자와 연결시 JCU-160의 CHECK SIGNAL 선택스위치를
출력펄스와 같게 설정하여 주십시요.
(CHECK SIGNAL선택스위치 설정 방법은 JCU-160메뉴얼 참조.)

1. SIGNAL INPUT TERMINAL

This is for input terminal of mixer or pre amplifier be sure not to 

change "+,-" polarity.

2. INPUT TERMINAL

input terminal for connection of signal input of amplifier.

Be sure not to change "+,-" polarity.

3. OUTPUT TERMINAL

Connect this to output terminal of amplifier. Br sure to connect 

amplifier built inoutput transformer if not, ground fault LED will be 

turn on.

4. SPEAKER TERMINAL

Connect this to terminal of amplifier in the relay group.

6. OUTPUT TERMINAL

Connect this to output terminal of spare amplifier.

(refer to systm diagram)

7. DC POWER (DC 24V)

This is for battery power, when unexpected AC power failure.

5. INUT TERMINAL / FAULT SIGNAL OUT

Connect this to signal input of spare amplifier.

FAULT SIGNAL OUTPUT : 

Fault signal come out from the above 

terminal. If you use 8main ampone spare amplifier or extended 

usage, be sure to connect signal output terminal of spare amplifiers

to JFA-242U, JFA-242 so as to change from main fault amplifier to 

spare amplifier when main fault. (refer to systm diagram)

IMPORTANT NOTICE : 

Be sure not to change "+,-" polarity. 

Use fuse rate : T1AH(55T)

8. AC POWER SOCKET 

This is ACpower socket.

IMPORTANT NOTICE : Check AC power and plug in power cord. 

Use fuse same type.

FUSE :120VAC

T1AL(S51), 220V~240VAC

T500mA(50T)

9. OUT TERMINAL FOR THE STATUS OF MAJOR FEATURE

This is output terminal to be connected with input terminal of JCU-160

in order to report the status of major features of equipment it self.

when connecting to JCU-160, please set "check signal" switch of 

JCU-160 to be matched with output pulse of this equipment.

( Please refer to the setting method of check signal switch in the

 operating manual of JCU-160)

Содержание JFA-242U

Страница 1: ...WWW JEDIA COM FAULT AUTO EXCHANGER JFA 242U...

Страница 2: ......

Страница 3: ...ot bending curved Do not install this apparatus in a confined space such as a book case or similar unit Locate this apparatus away from heat source such as radiators or other device that produce heat...

Страница 4: ...main amplifiers 1spare amplifier if you push IN switch of spare amplifier than fault signal will be supplied to spare amplifier 2 BUZZER OFF SWITCH Buzzer makes sound automatically when amplifier is o...

Страница 5: ...MINAL Connect this to output terminal of amplifier Br sure to connect amplifier built inoutput transformer if not ground fault LED will be turn on 4 SPEAKER TERMINAL Connect this to terminal of amplif...

Страница 6: ...DEL NO JFA 242U POWER CHECK NON PULSE FAULT CHECK NON PULSE FD 20 SLOT Priority Relay COM N O N C Ground Lift AC POWER REMOTE SERIAL NO G COM 25V 50V 100V COM 1 3 5 2 20 8 AC 230V 50Hz 1420W MODEL JPA...

Страница 7: ...S 232C UNIT NO RESET DC INPUT SUM OUTPUT 24V INPUT CHECK SIGNAL CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 CH 9 1 8 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 1 8 9 16 9 16 NON PULSE PULSE CHANNEL USE OFF...

Страница 8: ...EQUIPMENT TO RAIN OR MOISTURE 480DPT G Off Fault On Normal G GND OUT PRI CTL 24V 400Hz Normal FD20 Max 0 5A 0dBu 0 775V Priority Input 60k BAL 0dBu 0 775V PGM Input 60k BAL Level 0 10 DC POWER 24V 40...

Страница 9: ...espones Less than 0 5dB 20Hz 20KHz Signal to Noise Ratio More than 86dB No test signal 1 1 Level variable Power option AC 120V 220V 230V 240V 50 60Hz DC 24V Dimensions Weight 4 2Kg 9 3Ibs 483 W x 88 H...

Страница 10: ...F D R F D R VCC BUZZER GROUND FAULT LED OFF A SPARE AMP INPUT A SPARE AMP OUTPUT B SPARE AMP INPUT B SPARE AMP OUTPUT 2 3 4 2 3 4 SPARE AMP EXT FAULT SIGNAL OUT GROUP A GROUP B DC FUSE POWER SWITCH P...

Страница 11: ...M EMO...

Страница 12: ...JFA 242U OPERATING INSTRUCTIONS 4M OP207090 080106 FAULT AUTO EXCHANGER...

Отзывы: