T470 Part A User’s Manual © Jed Micro Pty Ltd 

Page 4 

This button allows an existing saved configuration for a T470 to be browsed to and opened. The file extension is “.cfg”. 
The system will remember the last directory in use, and allows a user-set-up filing system, e.g. by campus, then by 
wing, then by classroom. 

File tab | Save 

This allows the existing T470 configuration to be saved on disk in a user-set-up filing system. 

Help tab

 

This accesses a pdf help file for the Configuration Utility.  

Setting up T470 relay options 

Relay drive outputs from the Tx and Rx pins on the green Phoenix connector on the back are available if ordered as the 
“-R2” option. These are Solid-state relays (N-channel power FETs), not mechanical (with isolation) 

In a stand-alone T470 system (without the –R2 option), Relay 3 option of the RES settings is the only relay function 
available. 

All three relays in a stand-alone T470 system are set up in the lower-right hand side of the Config Utility. There are 
buttons for all relays, and a “clear-all” button. The “Function” window below the buttons shows (in text) the allocated 
function of the currently selected relay. If “None” is selected, the relay button is green, and it is red if active. Relay 3 is 
dimmed and un-selectable if the RES pin is set other than to “Relay 3 Out”. 

Note: If a relay function is set which needs TWO relays (e.g. screen down and screen up on separate relays) then 
the next relay numerically is reserved automatically, and an “Unavailable” message shows in the function 
window. 

The following table shows the functions available for any relay, with an explanation: 

Function No / Name 

Relay Function / Suggested Use 

00: None 

Key turns green, no allocation 

01: 1 Pulse Down / 1 Pulse Up 

Drive screens automatically at Display-device On/Off key activation (or 
manually via a “Screen” button) of type which needs a 2-second contact 
closure (on the first line to a common ground) to lower the screen, and a 
contact closure (on a second line to ground) to raise it. Assumes limit 
switches set travel. A “Screen” button can raise or lower the screen at 
any time before or during the Display-device on time. 

02: 1 Pulse Action / Alt Drive to 
Stop 

Drive screens automatically at Display-device On/Off key activation of a 
type which needs a 2-second contact closure (on the first line to a 
common ground) to begin screen-down travel, and a contact closure (on 
a second line to ground) to stop downwards travel. To raise the screen, 
a contact closure on the second line begins upward travel, and a 
contact closure on the first line stops travel. The time of downwards-
travel is automatically set from the display device “Warm-up” constant, 
and the screen up-travel time from the “Cool-down” time. These can be 
set in the “Timers” window. (No “Screen” button can be used with this 
type of screen, as timing is needed.) 

03: Pulse Action / 2 Pulses 
Together to Stop 

Drive screens automatically at Display-device On/Off key activation of a 
type which needs a 2-second contact closure (on the first line to a 
common ground) to begin screen-down travel, and a contact closure (on 
BOTH lines to ground) to stop downwards travel. To raise the screen, a 
contact closure on the second line begins upward travel, and a contact 
closure on BOTH lines stops travel. The time of downwards-travel is 
automatically set from the display device “Warm-up” constant, and the 
screen up-travel time from the “Cool-down” time. These can be set in 
the “Timers” window. (No “Screen” button can be used with this type of 
screen, as timing is needed.) 

04: Direct Drive for Warm-up / 
Cool- down Duration 

Direct control where contact time of first line sets down-travel time and 
contact time on second line determines up-travel time. The times are 
set by the “Warm-up” and “Cool-down” time settings. (No “Screen” 
button can be used with this type of screen, as timing is needed.) 
 

Содержание T470

Страница 1: ...New Zealand market Current consumption is approximately 50mA Connections and wiring to the T470 are covered in the later part of this manual page 6 Setting up the T470 To set up the T470 it is necess...

Страница 2: ...red between the RES pin and Ground It is internally pulled up by a 4k7 resistor in this mode In IR Out mode IR pulses are transmitted from the RES pin on the back of the T470 and assume a positive cur...

Страница 3: ...t to a phantom demo training mode Clicking on Factory Reset will select a default phantom display device Code 0000h which is quite useful for demo and testing purposes It sets valid English language m...

Страница 4: ...tton of type which needs a 2 second contact closure on the first line to a common ground to lower the screen and a contact closure on a second line to ground to raise it Assumes limit switches set tra...

Страница 5: ...device on time 21 On with On press Off at end of Cool down This is designed to drive a dipper which drops on relay closure and withdraws on relay open This allows full cool down while projector is des...

Страница 6: ...3 Source Key 4 Actioned 44 Source Key 5 Actioned 45 Source Key 6 Actioned 46 Source Key 7 Actioned 47 Source Key 8 Actioned 48 Source Key 9 Actioned Hardware connections to T470 The T470 mounts into s...

Страница 7: ...y connector only option This allows wiring to the screw terminals of power RS232 and IR out PIR in with nothing connected to the CAT5 connector Connection Function Gnd Ground Tx RS232 from T470 to pro...

Страница 8: ...outputs Relays they are actually solid state N FET transistors whose Source is connected to the common Ground of the system and Drain to the output terminal When OFF they are high impedance and when...

Страница 9: ...ion Res Pin must be configured for IR Out Connect IR Emitter as shown below Optional Jed IR Emitter is supplied with 2m of cable this can be extended and has been tested with 50m of CAT6 but care must...

Страница 10: ...T470 Part A User s Manual Jed Micro Pty Ltd Page 10 Mounting bracket for T470...

Отзывы: