there is air in the pump and the connector fitting. Don’t worry. Please plug on and off
for several times. it will work normally.
Used as submersible pumps
(
Figure 1
)
IMPORTANT: Do not let the pump run dry – this could cause
damage to the motor.
l
Submerse the pumps completely in your pond so as to make the pump body fill
with water.
l
A water level of approx. 15 cm (6.5 in.) is required for submersible use in order to
prevent the pump from taking in air.
l
To prevent the filter becoming prematurely clogged, place the fountain pump
above the mud in the pond!
l
Install the enclosed filter sponge to prevent the fountain inlet from becoming
clogged.
l
Running in conjunction with fountain jets, the pump should be stationed firmly
and horizontally (on a brick).
l
The pump can be switched on by simply plugging it in and switched off by
plugging off.
Used as non-submersible pumps
(
Figure 2
)
l
Position the pump lower than the water surface on the side of the pond so that the
water can be drained to the pump because it is not self-priming.
l
Remove the filter cover and connect suction hose (A: inlet) and pressure hose (B:
outlet) from the pump. The connection should be waterproof.
l
Fill the suction hose and pump with water before turning it on.
l
To prevent the pump from becoming clogged, provide the suction hose with an
adequate suction filter.
l
Never let the pump run dry.
Installation diagram
(
Figure 3
)
Figure 1 Figure 2
min.2m/6.0feet
15CM
place indoor
Adaptor
DCP Pump Controller
Figure 3
MAINTENANCE
To clean the pump, remove the back cover, sealing cover and the impeller.
Use a small brush or stream of water to remove any debris.
If the pump not work, check as following:
l
Check the circuit. Please try to plug on another power socket, to ensure the pump
switched on with power. Note, please do not plug on before operation.
l
Check the pump outlet and tube, if blocked by dirty. Algae may block them, up i
can clean the algae using the pond water with a garden hose.
l
Check the inlet to ensure not clogged by debris.
l
Remove the pump inlet to access the impeller. Turn around the rotor to check if
broken or jammed.
l
Monthly maintenance will prolong your pump’s life. Clean the rotor, remove the
dirt. etc
NOTE: Ensure the electrical cord loops below the power socket like a “Drip
Loop”. It will prevent the water from running around the cable into the power
socket
DISPOSAL:
Do not dispose this product as unsorted municipal waste. Collection
of such waste separately for special treatment is necessary. This
product must not be disposed together with the domestic waste. This
product has to be disposed at an authorized place for recycling of electrical and
electronic appliances. By collecting and recycling waste, you help save natural
resources, and make sure the product is disposed in an environmental friendly and
healthy way.
Jebao Co.,Ltd
Tongmao Industrical Park, Dongsheng Town, Zhongshan, Guangdong. China.
Email:
Tel: +86-760-28136717/19/20 Fax: +86-760-28136725
Outlet
Screw Nut
Controller
Adaptor
Holder
Rubber
Pump Body
Pump Cover
Rotor
O-Ring
O-Ring
Inlet
WATTS
DCP-200W
Pump Controller
A
B