MP-SerieS 

USB OPtical POwer Meter

Miniature USB optical power meter with 

FiberChekPRO™ integration

USer ManUal

Содержание MP Series

Страница 1: ...ZP PKG 0529 REV 1 MP SerieS USB Optical Power Meter Miniature USB optical power meter with FiberChekPRO integration User Manual...

Страница 2: ...ed States and other countries Tested Equipment All pre qualification tests were performed internally at JDSU while all final tests were performed externally at an independent accredited laboratory Thi...

Страница 3: ...Features 5 Software Installation 6 System Requirements 6 Operation Procedures 7 Hardware Recognition 7 Software Controls for OPM 8 Controls 9 REports 11 Default Path 11 Specifications 12 MP 60 Specif...

Страница 4: ...ointegratethemeasurementswithfiberinspectionand certification In addition it can also function as a stand alone device with a unique power measuring software Its size functionality and ease of use mak...

Страница 5: ...and archiving Using this program for inspection also requires a JDSU digital microscope Further information on the fiber inspection and analysis capabilities can be found in the FiberChekPRO user man...

Страница 6: ...Destination Location click Next d At the Select Components menu check all the components you want to install and make sure the box next to PDF PseudoPrinter is checked and click Next to continue e At...

Страница 7: ...nnected simply open additional applications accordingly Hardware Recognition JDSU USB OPMs Compatible with FiberChekPRO MP series FI series Connects with PC Yes Yes Connection type USB 2 0 USB 2 0 Fib...

Страница 8: ...g the box next to Link OPM readings with fiber analysis allows you to associate power meter readings with a fiber analysis see pg 10 for more details The Logging section allows you to setup an automat...

Страница 9: ...on allows users to measure a relative power attenuation in a link loss test which is measured in dB Simply press the REF button on the software to zero out the reading in dB for a reference measuremen...

Страница 10: ...pressing the button on the USB OPM device You can also integrate power meter readings into your inspection reports To enable this first go to the Setup Optical Power Meter and check the box that stat...

Страница 11: ...uments and Settings pc username My Documents JDSU FiberChekPRO Archives OPM Logs Default path for Windows 7 C Users pc username Documents JDSU FiberChekPRO Archives OPM Logs Each archived log includes...

Страница 12: ...nt types dB milliwatt dBm Power source USB port on PC or laptop Display range 65 to 10 dBm Max permitted input level 10 dBm Intrinsic uncertainty1 0 20 dB 5 Linearity1 50 to 5 dBm 0 06 dB Standard wav...

Страница 13: ...t types dB milliwatt dBm Power source USB port on PC or laptop Display range 50 to 26 dBm Max permitted input level 23 dBm Intrinsic uncertainty1 0 20 dB 5 Linearity1 50 to 5 dBm 0 06 dB Standard wave...