Chapter 9
Supervisor Commands
Descriptions of supervisory commands
CT-650 Command-Line Reference Guide
Release 9.4
89
Configure DCS
Configure DCS
Configures the interfaces between the CT-650 and the DCS. You can
change the following parameters:
Parameter
Description
DCS Number
Number identifying the DCS.
System Name
Name assigned to the DCS or RTU.
DCS Type
The type of DCS: 3/3, 3/1, 1/0, etc.
DCS Model (Lang)
Model of DCS. The available models depend on the selected DCS type
and installed features.
Protocol/SW Flow
Protocol and flow control appropriate for the DCS type and model.
Test Port Type
Test port type supported by the DCS.
Testhead Hostname
The host name for the CT-650 on the network. If the host name identifies
the CT-650 connected to the DCS control port, the remaining parame-
ters in this screen configure the TTY port connected to the DCS. If the
hostname identifies another CT-650, the local CT-650 gains access to
the DCS control port through the indicated CT-650. If
N/A
appears, the
CT-650 is not connected to a network.
Transport Type
Network transport protocol: RS232, IP, X.25, etc.
TTY Number
Old processor module—Number of TTY communication port: 2–11 for
the CT-650, or 2–7 for the CT-650s.
New processor module—Number of TTY communication port: 2–5 for
the CT-650, or 2–5 for the CT-650s.
If
N/A
, the CT-650 accesses the DCS through the network connection
and the indicated
Testhead Hostname
.
Baud Rate
Baud rate of the communication port.
Parity
Indicates the parity setting.
Data Bits
Number of data bits.
DCS Hostname/IP
Host name or IP address of the DCS (applies only to the Cisco 15454
ADM).
DCS IP Port
IP port address of the DCS (applies only to the Cisco 15454 ADM).
DCS User Name
User name for logging into the DCS (applies only to the Cisco 15454
ADM).
Содержание CT-650
Страница 1: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Страница 2: ......
Страница 3: ...CT 650 Wideband Test Unit Release 9 4 Command Line Reference Guide ...
Страница 4: ......
Страница 22: ...Contents xxii CT 650 Command Line Reference Guide Release 9 4 ...
Страница 104: ...Chapter 7 DS0 VF Test Commands Description of VF test commands 78 CT 650 Command Line Reference Guide Release 9 4 ...
Страница 108: ...Chapter 8 Batch Files Unavailable commands for batch files 82 CT 650 Command Line Reference Guide Release 9 4 ...
Страница 198: ...Appendix A Test Results Definitions Loopback status information 172 CT 650 Command Line Reference Guide Release 9 4 ...
Страница 240: ...Appendix D Customer Services and Support Training options 214 CT 650 User s Guide Release 9 3 ...
Страница 247: ......