JDS Labs C5 Скачать руководство пользователя страница 2

JDS Labs Model # C5 v1.01 | Instructions Rev. 6, December 2013 

 

 

Pg. 2 of 2 

 

Charging 

 C5 uses smart Li-Ion recharging technology, with typical charge time of 2-5 

hours. Connect a mini-USB cable to any USB outlet to begin charging. 

 

Amplifier may be used while charging, and USB cord may be 

connected/disconnected as desired.  

 

USB Noise: 

Some computers may impose noticeable ground loop noise while charging via USB and listening 

from the computer's audio jack. To resolve excess noise, use an AC-to-USB (wall) power adapter for charging. 

 

Specifications and Operating Conditions 

Amplifier Specifications 

Frequency Response 

+/- 0.1 dB 

THD+N (20-

20kHz, 150 Ω)

 

0.0015% 

THD+N (20-

20kHz, 32 Ω)

 

0.0045% 

Noise 

-105 dBu 

Crosstalk @ 150 

 

-67 dB 

Inter-channel Phase @ 1kHz 

+/- 0.01 degrees 

Channel Balance 

+/- 0.55 dB 

Max Output @ 600Ω

 

4.146 VRMS 

Max Output @ 150Ω

 

3.580 VRMS 

Max Output @ 32 

 

1.182 VRMS 

Power Supply 

14.0 Vpp 

Output Impedance 

0.62 

 

Battery Run Time 

11-14 Hours* 

Charge Time 

2-4 Hours 

Operating Temp 

0°C to 60°C 

Operating Humidity 

0 to 85% Relative 

Dimensions 

99.5 x 61.5 x 14.0 mm 

Weight 

4.2 ounces 

 

Test equipment: PrismSound dScope Series III audio analyzer, Tektronix TDS1012 oscilloscope 

*Run time and charge time observed under typical usage. Actual run time will vary with equipment and volume. 

 

 

 

ATTENTION:

 Battery must only be replaced with equivalent 3.7V, 1200mAh Li-Ion pack. Misuse of 

the battery may cause fire or burns. JDS Labs, Inc. is not responsible for damages caused by 

device misuse, or failure to adhere to device instructions.  

 

FCC Certifications 

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the  FCC Rules. These limits are designed to provide reasonable 

protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not 

installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause 

harmful interference in which case the user will be required to correct the interference at his own expense. 

 

CE Mark Warning 

This equipment complies with the requirements relating to electromagnetic compatibility, EN 55022 class A for ITE, the essential protection requirement of Council Directive 89/336/EEC on 

the approximation of the laws of the Member States relating to electromagnetic compatibility. 

Amplifier 

LED Status 

Off 

Off 

On 

Solid Green 

Low Battery  Flashing Green 
Charging 

Blue 

Отзывы: