중요사항 : 휴즈를 교체시에는 반드시 규정된 정격 휴즈를 
자격이 있는 사람이 휴즈를 교체 하십시오.

4. AC/DC FUSE

3

MODEL

DA-2501P

DA-2502P

T2AL 250V

T3.15AL 250V

T15AL 32V

T20AL 32V

DA-2504

T6.3AL 250V

T40AL 32V

DA-5001P

T3.15AL 250V

T20AL 32V

DA-5002P

T6.3AL 250V

T40AL 32V

DA-1000P

T6.3AL 250V

T40AL 32V

VOLTAGE

AC220V, 230V, 240V ~

DC 24V

MODEL

DA-2501P

DA-2502P

100V  /  40Ω

100V  /  40Ω

DA-2504

100V  /  40Ω

DA-5001P

100V  /  20Ω

DA-5002P

100V  /  20Ω

DA-1000P

100V  /  10Ω

IMPEDANCE

IMPORTANT : When fuse is blown out, it should be replaced with
same type just like following table, if it continues to blown out,
stop replacing fuse and 
refer servicing to qualified 
person.

4. AC/DC FUSE

R

EAR PANEL CONTROLS 

(후면기능)

FAULT DETECTOR MODULE(FD-200)을 장착하기 위한 슬롯입니다.

5. FD-200 SLOT

스피커와 임피던스 매칭을 쉽게 하기위해 100V 출력으로 설계되어 
있습니다

6. 앰프출력 단자

: 본단자에 접촉시 전기적 충격이 있을수 있습니다. 기기의 결선등 으로
  부득이 접촉 해야할 경우 반드시 기기의 전원을 끄고 작업 하십시오.

PROGRAM 오디오 신호(일반방송)를 위한 입력단자로서 스크류 터미널로    
설계되어 있습니다. 정상입력 레벨은 0dBu(0.775V) 30K    바란스 형태입
니다. 동일한 입력신호를 앰프에 병렬로 공급할 경우는 아래 그림과 같이  
링크하여 사용하십시오. 

7. PROGRAM 오디오 입력단자 

7. PROGRAM AUDIO INPUT TERMINALS 

Audio input terminal of PROGRAM signal(for normal announcement) with 

screw terminal.  

Input level is 0dBu (0.775V) 30K     balanced.

Please make external wire link as below in case of using amplifier in serial 

connection.

This makes reduction of resonance sound inside to make a clear 

sound when pushing H.P.F

Set the switch FD-200 for use of FD-200. 

Be sure to set switch Normal, not using FD-200.

Setting of switch is Normal position, When factory production.

8.  200Hz FILTER , FD-200 ON/OFF 스위치

이 스위치를 "ON" 위치로 설정하면 200Hz H.P.F를 통과하여 
실내 공진음을 감소시켜 음질의 명료도를 향상시킬수 있습니다.   

기능을 사용하고자 할때 이 스위치를 FD-200 위치로 하십시오. 
단 FD-200 기능을 사용하지 않을때는 반드시 이 스위치를 
Normal위치로 설정하십시오. 
공장 출하시 이 스위치는 Normal 위치로 설정 되어 있습니다.

FAULT DETECTOR MODULE (FD-200)을 장착하여 FD-200 

 .  200Hz  ON/OFF (H.P.F)

1

 . FD-200 ON/OFF 스위치

2

8.  200Hz FILTER , FD-200 ON/OFF SWITCH

 .   200Hz  ON/OFF 

SWITCH (HPF)

1

 . FD-200 ON/OFF SWITCH 

2

G

G

PGM INPUT

AMP-1

AMP-2

0dBu(0.775V)

PGM

AUDIO INPUT

30K    BAL

LINK

G

PGM INPUT

AMP-1

1-CHANNEL

2-CHANNEL

0dBu(0.775V)

PGM

AUDIO INPUT

30K    BAL

5. FD-200 SLOT

This is slot for installation of FD-200 (Fault Detector Module)

Amplifier is designed to 100V output to simple matching for speaker and 
impedance.

6. AMP OUTPUT TERMINALS

Содержание DA-2501P

Страница 1: ...JD MEDIA DIGITALPOWERAMPLIFIER DA 2501 2502 2504 5001 5002 1000 DA 2501P 2502P 5001P 5002P 1000P...

Страница 2: ...if possible recommand temperature at the range 15 to 30 2 How to forward goods recommand shipping by sea or truck with container or pallette packing 3 disassembling and re cycling 4 serial number inf...

Страница 3: ...us do not open top cover Connect the power cord with safety after check of AC power Amplifiers should be serviced by qualified service person 1 2 DC 300V 1 FEATURES 1 High efficificate of PWM amplifie...

Страница 4: ...0Hz 1200W AC FUSE T10AL 250V FD 200 Fault Detector option FD 200 Fault Detector option COM 100V 20 COM 100V 20 AMP 2 AMP 1 POWER AMPLIFIER MODEL DA 5002P AMP 1 AMP 2 0 Level 10 G 0 Level 10 0 ON OFF L...

Страница 5: ...uncement with screw terminal Input level is 0dBu 0 775V 30K balanced Please make external wire link as below in case of using amplifier in serial connection This makes reduction of resonance sound ins...

Страница 6: ...t is turned right by screwdriver priority input signal is increased 10 PRIORITY LEVEL ADJUSTMENT 1 For switch or relay contact 1 Connect terminal of AMP PRIORITY CONTROL OUT of RG 3220 When control PR...

Страница 7: ...nside temperature of rack system so as COOLING IMPORTANT NOTICE Radio receiver TV and other wireless MOUNTING not to be more than 40 C for the stable operating in any case we recommend you to install...

Страница 8: ...be higher than that of output impedance of amplifier 1 6 Method of matching trans calculation SPK Q TY Series output amp wattage SPK output wattage per piece EX In case SPK output power requirement i...

Страница 9: ...IERS FD 200 4 FD 200 ON OFF FD 200 1 Set Digital Portable Multimeter to measure AC voltage and Confirm output of power amplifier is 2Vac RMS at 20KHz Adjust OSC LEVEL potentiometer VR602 If necessary...

Страница 10: ...wer on off Short detect E B Program Peiority E B hot cold com hot cold com EXCHANGE GND PRIORITY CON SUM FD 200 CARD OPTION on off MUTE CONTROL PROT Power SW AMP FAULT PROT SIG CLIP INPUT BOARD AMP BO...

Страница 11: ...40 DA 2502P 100V 40 DA 2504 100V 40 DA 5001P 100V 20 DA 5002P 100V 20 DA 1000P 100V 10 OUTPUT IMPEDANCE 0dBm 0 775V 30 BALANCED INPUT LEVEL OVER LOAD OUT SHORT SOFT START OTP PROTECTION 220 240V 50 60...

Страница 12: ...www jdmglobal co kr 18633 445 935 23 Eunhaengnamu ro 170beon gil Yanggam myeon Hwaseong si Gyeonggi do Tel 82 31 366 6400 Fax 82 31 366 6404 C N 4M10 DPL010 02 JD MEDIA CO LTD...

Отзывы: