12. Example of the download procedure
(1) Press F key (capital letter) to start the download program.
(2) Downloading starts. The LEDs 1 and 2 on the CPU board flashes alternatively.
(3) When the downloading is completed, LED1 and LED2 flash in unison.
Dev.=fc Port=2 File=2420710.USA DWLD01:00200000:0027FFFF 91DO 38400bps
RUN
1
DOWN LOAD PROGRAM Ver.
I: Addressed Reset
G: Global Reset
F: File Download
Ctrl - f: File Download (Selection)
214-00 05/JUN/’03 JCM
V :Version Information Request
Ctrl - X: Abort
P: Program Check Verify
S: Set Start Addr. & Seed Val.
(Start Addr.: 000000 Seed Val.: 0000)
Device Ver. :
Vaildator Status: Disable
Comm Status: OK
Poll - - ->
<- - - Bill Validator Disabled
Selected serial port No.
Entered download filename.
If the download file is correct, "DWLD01" is shown here.
Baud rate
4
3
2
1
OFF
Execution Screen
When the program starts, the following screen appears.
Note: If the download file is correct, “DWLD01” appears on the top line.
Operation:
Use the letter keys to enter a command.
I
:
Addressed Reset - Reset a selected unit in the game machine.
V
:
Version Information Request - Reads the program version after downloading is complete.
G
:
Global Reset - Reset all the units (including WBA) connected to the host controller
Ctrl + X
: Abort - Exit the program.
F
:
File Download - Downloads the specified file.
P
:
Program Check Verify - Check CRC by the WBA itself.
Ctrl + F
: File Download (Selection) -
DO NOT USE THIS COMMAND
S
:
Set Start Addr. & Seed Val. - The start address and initial value of CRC when checking CRC.
Mod
elnumbers
Spe
c
ificati
o
n
s
Operatio
n Ma
nual
C
o
mmun
icati
on
Spe
c
ificati
o
n
s
Disassembly
Assembly
W
iring Diagram
Tr
ouble S
h
o
o
ting
Cali
brati
on
So
ft
ware
Do
wn
lo
ad
Pa
rts List
WBA-SS Service Manual
- 11 -